TECHNET Archives

October 2005

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Wee Mei <[log in to unmask]>
Date:
Thu, 20 Oct 2005 13:36:31 +0800
Content-Type:
text/plain
Parts/Attachments:
text/plain (295 lines)
Chuck,

I am not a process gal but would like to learn more. Why the smell of
ammonia when the blister is cut?

Regards,
Wee Mei

----- Original Message -----
From: "Brummer Chuck" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Thursday, October 20, 2005 2:46 AM
Subject: Re: [TN] Delamination at Thermal Via area?


> Hi,
>
> I stayed quiet before because it looked like several people had some great
> clues to your problem.
> But with these other pictures, it would appear to me that there was a
> problem with moisture or water in the lay up.  If you cut a blister an
> smell
> ammonia, then there was water present when the board was laminated.
>
> Chuck Brummer
> Siemens/AIM
>
>
> -----Original Message-----
> From: Steve Gregory [mailto:[log in to unmask]]
> Sent: Wednesday, October 19, 2005 10:49 AM
> To: [log in to unmask]
> Subject: Re: [TN] Delamination at Thermal Via area?
>
>
> Hi George!
>
> Got your pictures up! Check out:
>
> http://www.stevezeva.homestead.com/files/Delamination_Blisters-1.jpg
> http://www.stevezeva.homestead.com/files/Delamination_Blisters-2.jpg
> http://www.stevezeva.homestead.com/files/Delamination_Blisters-3.jpg
>
> Kind regards,
>
> -Steve Gregory-
> Senior Process Engineer
> LaBarge Incorporated
> Tulsa, Oklahoma
> (918) 459-2285
> (918) 459-2350 FAX
>
>
>
> |---------+---------------------------->
> |         |           "Wenger, George  |
> |         |           M."              |
> |         |           <George.Wenger@an|
> |         |           drew.com>        |
> |         |                            |
> |         |           10/19/2005 11:00 |
> |         |           AM               |
> |         |                            |
> |---------+---------------------------->
>
>>---------------------------------------------------------------------------
> -----------------------------------|
>  |
> |
>  |       To:       TechNet E-Mail Forum <[log in to unmask]>@SMTP@Exchange,
> Stephen R Gregory/LABARGE@LABARGE      |
>  |       cc:
> |
>  |       Subject:  RE: [TN] Delamination at Thermal Via area?
> |
>
>>---------------------------------------------------------------------------
> -----------------------------------|
>
>
>
> Wee Mei,
>
> I've asked Steve to post three images of delamination blistering that
> might be different than you are seeing but the cause is most likely the
> same.  I do not know how many layers there are or the number of thermal
> vias there are in the heat spreader portion of the U2 footprint on your
> board but it appears that your delamination is occurring in an area of
> the board where the outside layers are totally covered by metal (i.e.,
> copper).  This is decrease the ability of the board to outgas in those
> areas if the board is heated too rapidly or to too high a temperature.
> I'm also assuming but can't tell because I haven't seen a cross section
> of your thermal vias but my guess would be that you do not have good
> attachment integrity of the outer-layer copper to the barrels of the
> thermal vias and therefore the thermal vias are not providing any
> mechanical strength to hole you board together when reflowed.  The three
> images I've sent to Steve show delamination blisters on the bottom side
> of a 14-Layer PCB.  The delamination is occurring between layer 13 and
> layer 14 in areas that have a copper ground plane on Layer 14.  There
> acre also not PTH's in these areas to hold the board together when
> internal moisture is driven off too fast.  There are no blisters where
> ever there are PTH's.  We're not sure there was a single cause for our
> delamination or multiple causes.  These boards were over 1 year old and
> could have and probably did absorb moisture from the environment.  We
> believe the reflow profile that caused these blisters had too fast a
> ramp and too hot a peak temperature.  If we baked the boards prior to
> the reflow they didn't delamination or if we didn't bake the boards and
> used a correct profile they didn't blister.  I hope this information
> helps you find the root cause for you delamination.  My suggestion is to
> examine your reflow profile and cross section thermal vias in the
> blistered area.
>
>
> Regards,
> George
> George M. Wenger
> Reliability / FMA Engineer
> Base Station and Subsystems Group
> Andrew Corporation, 40 Technology Drive, Warren, NJ 07059 (908) 546-4531
> [log in to unmask]
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Steve Gregory
> Sent: Wednesday, October 19, 2005 10:30 AM
> To: [log in to unmask]
> Subject: Re: [TN] Delamination at Thermal Via area?
>
> Hi Wee Mei!
>
> I've got your pictures posted. Go to:
>
> http://www.stevezeva.homestead.com/files/U2_top.JPG
> http://www.stevezeva.homestead.com/files/U2_bottom.JPG
> http://www.stevezeva.homestead.com/files/U2_delamination.JPG
>
> Are the vias filled? Are you seeing this delamination on very many
> PCB's? Are you seeing it only on the bottom of the PCB?
>
> Kind regards,
>
> -Steve Gregory-
> Senior Process Engineer
> LaBarge Incorporated
> Tulsa, Oklahoma
> (918) 459-2285
> (918) 459-2350 FAX
>
>
>
> |---------+---------------------------->
> |         |           Wee Mei          |
> |         |           <[log in to unmask]
> |         |           SG>              |
> |         |           Sent by: TechNet |
> |         |           <[log in to unmask]>|
> |         |                            |
> |         |                            |
> |         |           10/19/2005 03:47 |
> |         |           AM               |
> |         |           Please respond to|
> |         |           TechNet E-Mail   |
> |         |           Forum            |
> |         |           <[log in to unmask]>|
> |         |           ; Please respond |
> |         |           to Wee Mei       |
> |         |           <[log in to unmask]
> |         |           SG>              |
> |         |                            |
> |---------+---------------------------->
>
>>-----------------------------------------------------------------------
> ---------------------------------------|
>  |
> |
>  |       To:       [log in to unmask]@SMTP@Exchange
> |
>  |       cc:       (bcc: Stephen R Gregory/LABARGE)
> |
>  |       Subject:  [TN] Delamination at Thermal Via area?
> |
>
>>-----------------------------------------------------------------------
> ---------------------------------------|
>
>
>
> Hello,
>
> Just asked Steve to download 3 pictures on the defects. Kindly take a
> look at them and would appreciate some feedback on the possible root
> cause.
>
> Steve : Thanks for the downloading.
>
> Regards,
> Wee Mei
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
> unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
> (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing
> per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at:
> http://listserv.ipc.org/archives Please visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at [log in to unmask]
> or 847-615-7100 ext.2815
> -----------------------------------------------------
>
>
>
> __________________________________________________________________
> This message may contain information that is privileged and confidential
> to LaBarge, Inc.  It is for use only by the individual or entity named
> above.
> If you are not the intended recipient, you may not copy, use or deliver
> this message to anyone.  In such event, you should destroy the message
> and kindly notify the sender by reply e-mail.
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
> unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
> (re-start) delivery of Technet send e-mail to [log in to unmask]: SET
> Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
> posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
> archives of previous posts at: http://listserv.ipc.org/archives Please
> visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
> additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>
> ----------------------------------------------------------------------------
> --------------------
> This message is for the designated recipient only and may
> contain privileged, proprietary, or otherwise private information.
> If you have received it in error, please notify the sender
> immediately and delete the original.  Any unauthorized use of
> this email is prohibited.
> ----------------------------------------------------------------------------
> --------------------
> [mf2]
>
>
>
> __________________________________________________________________
> This message may contain information that is privileged and confidential
> to
> LaBarge, Inc.  It is for use only by the individual or entity named above.
> If you are not the intended recipient, you may not copy, use or deliver
> this message to anyone.  In such event, you should destroy the message and
> kindly notify the sender by reply e-mail.
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
> for additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2