Arnaud GRIVON <[log in to unmask]>
Reply To:
Date:
Tue, 4 Oct 2005 17:21:07 +0200
Content-Type:
text/plain
Parts/Attachments:
text/plain (42 lines)
Werner Engelmaier a écrit :

>Hi Arnaud,
>You did not say whether this is rolled or ED copper. Also, the way you
>described it, you may have a stres concentration geometry.
>You will have a problem with correlating Vickers hardess to ductility,
>particularly since ductility is directional and vickers is not. However, you should
>be able to determine whether there is something different with the failure
>location copper.
>
>
>
>Werner
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 1.8e
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
>-----------------------------------------------------
>  
>
Werner,

To answer your question, the flex structure is based on a double sided 
50µm polyimide without adhesive (35µm RA copper).
Each side of this core has a 50µm acrylic adhesive layer and a 25µm 
coverlay.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2