Buehler has this handy little device;

www.buehler.com/productinfo/2004EBG/speciality_equipment.pdf

And it cost $2500, their 6 mount system is $4500

We have the setup for 6 and 9 mounts but there are times when I need or want
to do a single puck and my choice is do it by hand or make up 5 blanks to
keep balance on the 6 opening wheel.

Certainly Buehler is not the only one making that single mount setup?

Franklin

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Susan Mansilla
Sent: Friday, October 07, 2005 8:23 AM
To: [log in to unmask]
Subject: Re: [TN] Microsection

Hi Franklin
30 plus years ago we had one of those devices and used it for printed wiring
boards.  However, I was told by Buehler and several others that this handy
little device should not be
used for printed wiring boards.  It was developed for hard metals and you
could have distortions if you used it to process smaller printed wiring
boards.

So, in my humble opinion, you have two choices.  Continue doing one mount at
a time by hand or perhaps purchase a smaller bench type version that has a
head that accomodate 3 - 6 mounts.

Susan Mansilla
Robisan Lab

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2