Dear Technetters,

I have searched MIL-PRT-55110F and found that there are differences in testing processes and acceptibility criteria in between MIL-P-55110D and MIL-P-55110E but I did not get adequate information to clearly state the differences. I think to do this, I need to find the standards. Could you please send me the copies, if you have?

Regards

Sefika


-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Franklin Asbell
Sent: Friday, October 07, 2005 4:00 PM
To: [log in to unmask]
Subject: Re: [TN] mil-p-55110 d/e

There are many approaches one can take.

Some shops develop procedures to cover all rev levels but this is not always
necessary.

In MIL-PRF-55110F there are guidelines to be used to cover the varied
requirements.

Most early drawings spell out MIL-P-55110 without a rev level. When the rev
level is not called out one would use the most recent rev.


If the purchase order specifies a specific revision, say D, then the shop
would be required to follow D. There are very few situations where a buyer
would specify D and actually need it fabricated to that level. Most often
the use of early revs i.e. D, E, is because "we've always done it this way"
and when explained to them they readily apply the most recent rev or simply
apply MIL-PRF-55110 on documents.

It's confusing to many until explained.

Franklin

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Blair K. Hogg
Sent: Friday, October 07, 2005 7:30 AM
To: [log in to unmask]
Subject: Re: [TN] mil-p-55110 d/e

Indeed. I am also curious. It was my understanding, although I haven't
worked with Mil specs in some time, that on any mil-type contract the
supplier is allowed to use the latest revision of any mil spec, regardless
of what is called out.


Now the real problem is if the PCB is designed to D, and the customer is
insisting on at least E revision. I think that is his real question.


Blair

>>> [log in to unmask] 10/07/05 05:22AM >>>
I suggest getting 55110F and reviewing it. There is an explanation of the
differences between D, E, and F. The current revision is F amendment 1.

If you fabricate to the requirements of D, it will not satisfy E; moreover,
if you fabricate to E, it will not satisfy F or F1.

The current version F has an inspection plan that may be used to satisfy the
earlier versions.


I'm curious why you're stuck back on D and E.

Franklin

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Sefika ÖZKAL
Sent: Friday, October 07, 2005 3:13 AM
To: [log in to unmask]

Subject: [TN] mil-p-55110 d/e

Dear Technetters,

I need MIL-P-55110 D and MIL-P-55110 E standards, I have searched internet
but I can reach only MIL-PRT-55110 F. I have to learn the differences
between E and D revision of the standard.


Moreover will the pcb which is manufactured by MIL-P-55110 D will satisfy
MIL-P-55110 E?

Regards

Sefika



Dikkat :
Bu elektronik posta mesaj (Mý kiþiseldir. Eðer, gönderilmesi
gereken kiþi deðilseniz lütfen göndericiyi bilgilendirip
mesajý siliniz. Firmamýza gelen ve giden mesajlar virüs
taramasýndan geçirilmekte, hukuki nedenlerle log kayýtlarý
tutulmaktadýr. Mesajdaki görüþler ve bakýþ açýsý göndericiye
ait olup Aselsan A.Þ. resmi görüþü olmak zorunda deðildir.

Attention :
This e-mail message is private.
If you are not the intended recipient please delete
the message and notify the sender. E-mails to and
from the company are, monitored for virus protection
and in accordance with lawful business practices.
Any views or opinions presented are solely those of the
author and do not necessarily represent the views of
Aselsan A.S.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives

Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16

for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives

Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

*******************************************************************
This email and any files transmitted with it are confidential and
intended solely for the use of the individual or entity to whom they
are addressed. If you have received this email in error please notify
the system manager.

This footnote also confirms that this email message has been swept
for the presence of computer viruses.

www.hubbell.com - Hubbell Incorporated

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------



Dikkat :

Bu elektronik posta mesajı kişiseldir. Eğer, gönderilmesi
gereken kişi değilseniz lütfen göndericiyi bilgilendirip
mesajı siliniz. Firmamıza gelen ve giden mesajlar virüs
taramasından geçirilmekte, hukuki nedenlerle log kayıtları

tutulmaktadır. Mesajdaki görüşler ve bakış açısı göndericiye
ait olup Aselsan A.Ş. resmi görüşü olmak zorunda değildir.

Attention :
This e-mail message is private.

If you are not the intended recipient please delete
the message and notify the sender. E-mails to and

from the company are, monitored for virus protection
and in accordance with lawful business practices.
Any views or opinions presented are solely those of the
author and do not necessarily represent the views of
Aselsan A.S.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2