Why fill then cap the vias? Via capping alone should work
without via filling. Keep in mind that via capping is with
a dryfilm soldermask then covered with an LPI soldermask.
It does cost more for this approach so it should only be
used if via plugging won't work for you. (via plugging
typicllay fills 1/3 of the barrel of the via and should
only be done from one side.)
Thank you,
Eddie Rocha
South Bay Circuits
Hello, all,
Since the designers (whos vision of the product has a gap
starting in the end of the PCB design until they see the
assembled board) placed capacitors on the fan-out vias of
every 1 mm BGA. No need to say that the vias are through
holes, with drill diameter of 0.3 mm (12 mils). This
doesn't leave much hope for the soldering. My solution is
to fill the vias, then cap them.
Can somebody suggest DFM for the PCB design, that will ease
the PCB manufacturer's task? I mean - the minimum common
baseline, so maximum fabricators will be able to deal with
it.
Regards
Ofer Cohen
Seabridge - a Siemens company
---------------------------------------------------
Technet Mail List provided as a service by IPC using
LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with
following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send
e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send
e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at
[log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|