-----Original Message-----
From: Byram, Jody L
Sent: Wednesday, September 28, 2005 3:36 AM
Apply the label in a portion of the CCA that is all at the same
potential, in an area where it is surrounded by components .  At 25kV,
electric field even on the edge of the label can become a concern if
there is ground potential "nearby" (i.e. within 2 or 3 inches or so).
Ink marking is also OK, again as long as it is done on a copper plane.
Resistist the temptation to mark in the 3 inch wide "no-man's-land"
between 25kV and ground, because that is where the fields are the
highest.  Marking on the inside edge of a corona ring (if used) is also
a possibility.  Inside shielded edge, not the outside surface of course.

Thanks,
Jody Byram

Sr. Staff Design Engineer
LMCSS - Newtown
215-497-1769

> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]]On Behalf Of Alcorn, Brent
> Sent: Friday, September 23, 2005 11:26 AM
> To: [log in to unmask]
> Subject: [TN] Marking product that are extremely high voltage.
>
> Hi folks,
>
> I need to label/mark, a not so large board, that comprises of mostly
> 25KV.  Our standard paper labels are out of the question (due to
> proximity of circuitry to the label); so I was wondering if any of you
> have some ideas.
>
> Thanks,
> Brent

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2