My customer told me that one of the RF pcb need to maintain the 5mils trace
width within 5% tolerance in order to achive 50 ohms impedance.
My pcb maker said they can only control at 20%(copper etching process
capability) trace width tolerance BUT can guarantee that the impedance is
at 50 ohms.
Please comment.Should I take the words of pcb supplier?

rgds
sumxp

---------------------------------------------------