-----Original Message-----
From: Wenger, George M. 
Sent: Monday, September 12, 2005 8:23 PM
To: 'John Burke'; 'TechNet E-Mail Forum'
Subject: RE: [TN] raised vias...

 

John,

 

We won't know for sure until Steve does a cross section but my
assessment right now is that the raised ant hills are all too uniform to
be unfilled vias that have solder being pushed out.  When I look at the
photograph it looks like a continuous sheet of copper that has bulged
areas rather than ant hills with an opening due to outgassing.

 

Regards, 
George 
George M. Wenger, Andrew Corporation 
Reliability / FMA Engineer 
Base Station & Subsystems Group 
40 Technology Drive, Warren, NJ 07059 
(908) 546-4531 [log in to unmask] 
  

-----Original Message-----
From: John Burke [mailto:[log in to unmask]] 
Sent: Monday, September 12, 2005 8:15 PM
To: 'TechNet E-Mail Forum'; Wenger, George M.
Subject: RE: [TN] raised vias...

 

I think they are not filled, I believe the HASL process filled the vias
(horizontal HASL). I also think that the very thick core kept the via
hole solder molten long enough after process for the outgassing taking
place in the via holes to push the solder back out of the via forming
the ant hills.

Who knows...............Section it Steve................... 

John 

------------------------------------ 
Avanex 
John Burke 
Senior Manager RoHS Compliance 
[log in to unmask] 
40919 Encyclopedia Circle 
Fremont 
CA 94538 
tel: 510 897 4250 
fax: 510 979 0189 
mobile: 510 676 6312 
------------------------------------ 

 

-----Original Message----- 
From: TechNet [mailto:[log in to unmask]]On Behalf Of Wenger, George M. 
Sent: Monday, September 12, 2005 4:57 PM 
To: [log in to unmask] 
Subject: Re: [TN] raised vias... 

 

Michael, 

  

I've taken a closer look at the raised via photo on Steve's site and I 
agree the board does appear to have HASL surface finish and a cross 
section should eliminate any  guess work as to the cause for the raised 
via.  I would be more worried with Layer 1 copper plating attachment to 
the via barrel plating than I would to the via fill material. 

  

Regards, 
George 
George M. Wenger, Andrew Corporation 
Reliability / FMA Engineer 
Base Station & Subsystems Group 
40 Technology Drive, Warren, NJ 07059 
(908) 546-4531 [log in to unmask] 
  

-----Original Message----- 
From: Mcmaster, Michael [mailto:[log in to unmask]] 
Sent: Monday, September 12, 2005 7:44 PM 
To: 'TechNet E-Mail Forum'; Wenger, George M. 
Subject: RE: [TN] raised vias... 

  

I would bet they were planarized down to the surface initially.  It 
looks like the board has HASL surface finish and I would bet the resin 
in the vias expanded, pushing out the copper which then stayed there. 

Cross section should show whether the copper is still attached to the 
via fill.  

This is one of the problems of trying to use prepreg resin to fill vias.

The resins meant to fill vias generally give better plating adhesion and

don't show this "bullet hole" appearance. 

  

-----Original Message----- 
From: TechNet [mailto:[log in to unmask]] On Behalf Of Wenger, George M. 
Sent: Monday, September 12, 2005 4:36 PM 
To: [log in to unmask] 
Subject: Re: [TN] raised vias... 

Valerie, 

I think I agree with you that the bumps are prepreg and that the 
fabricator needs to plane the prepreg back down to the copper level. 
However, the problem with doing that is control of the plane operation 
so it doesn't remove too much copper and weaken the Layer 1 via knees. 
My suggestion to Steve is to cross section some of the raised vias and 
examine the integrity of the Layer 1 plating to the blind via barrel 
plating.  And I would also repeat the cross sectioning process on 
reflowed bare boards after the fabricator eliminates the raise vias to 
insure he has good interconnect integrity/reliability. 

Regards, 
George 
George M. Wenger, Andrew Corporation 
Reliability / FMA Engineer 
Base Station & Subsystems Group 
40 Technology Drive, Warren, NJ 07059 
(908) 546-4531 [log in to unmask] 
  

-----Original Message----- 
From: TechNet [mailto:[log in to unmask]] On Behalf Of Valerie St.Cyr 
Sent: Monday, September 12, 2005 7:18 PM 
To: [log in to unmask] 
Subject: Re: [TN] raised vias... 

Nope .... those vias are filled with prepreg from the lamination cycle. 
It 
had nowhere to go ... it melts and floods up the hole, capillary action.


The fabricator should have planed the surfaces to bring the prepreg back


down level to the copper layer. 

Valerie 






stephen gregory <[log in to unmask]> 
Sent by: TechNet <[log in to unmask]> 
09/12/2005 07:02 PM 
Please respond to TechNet E-Mail Forum; Please respond to stephen 
gregory 

  

        To:     [log in to unmask] 
        cc: 
        Subject:        Re: [TN] raised vias... 

  

Hi Everyone! 

I'm home now, but I can answer some of the questions. 

The picture of the board is as it was given to us. It hasn't been 
through 
reflow...this is how the bare board looks. 

The vias aren't filled.This is a 10-layer board that is made from 
IPC-4101/26 
(GF) material. BUT, there is 5-layers on one side of a .045" thick 
copper 
core, 
and on the other side of the core is the other 5-layers. There is 
double-sided 
SMT on the board, and both sides have the "anthills" like you see in the


picture. 

Pretty strange, huh? 

-Steve Gregory- 

  

"Brooks,Bill" <[log in to unmask]> wrote: 
I'm just passing the message on... it's Steve's board... 

Thanks, 

Bill Brooks 






--------------------------------------------------- 
Technet Mail List provided as a service by IPC using LISTSERV 1.8e 
To unsubscribe, send a message to [log in to unmask] with following text 
in 
the BODY (NOT the subject field): SIGNOFF Technet 
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL) 
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest 
Search the archives of previous posts at: 
http://listserv.ipc.org/archives 
Please visit IPC web site 
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional 
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100


ext.2815 
----------------------------------------------------- 

------------------------------------------------------------------------

------------------------ 
This message is for the designated recipient only and may 
contain privileged, proprietary, or otherwise private information.  
If you have received it in error, please notify the sender 
immediately and delete the original.  Any unauthorized use of 
this email is prohibited. 
------------------------------------------------------------------------

------------------------ 
[mf2] 

--------------------------------------------------- 
Technet Mail List provided as a service by IPC using LISTSERV 1.8e 
To unsubscribe, send a message to [log in to unmask] with following text 
in 
the BODY (NOT the subject field): SIGNOFF Technet 
To temporarily halt or (re-start) delivery of Technet send e-mail to 
[log in to unmask]: SET Technet NOMAIL or (MAIL) 
To receive ONE mailing per day of all the posts: send e-mail to 
[log in to unmask]: SET Technet Digest 
Search the archives of previous posts at: 
http://listserv.ipc.org/archives 
Please visit IPC web site 
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional 
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100

ext.2815 

----------------------------------------------------- 

------------------------------------------------------------------------
------------------------ 
This message is for the designated recipient only and may 
contain privileged, proprietary, or otherwise private information.  
If you have received it in error, please notify the sender 
immediately and delete the original.  Any unauthorized use of 
this email is prohibited. 
------------------------------------------------------------------------
------------------------ 

--------------------------------------------------- 
Technet Mail List provided as a service by IPC using LISTSERV 1.8e 
To unsubscribe, send a message to [log in to unmask] with following text
in 
the BODY (NOT the subject field): SIGNOFF Technet 
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL) 
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest 
Search the archives of previous posts at:
http://listserv.ipc.org/archives 
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815

----------------------------------------------------- 
[mf2] 

------------------------------------------------------------------------------------------------
This message is for the designated recipient only and may
contain privileged, proprietary, or otherwise private information.  
If you have received it in error, please notify the sender
immediately and delete the original.  Any unauthorized use of
this email is prohibited.
------------------------------------------------------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
[mf2]

ATOM RSS1 RSS2