Hi Sumxp (couldn't bring myself to say hi no name....!),

What is the percentage of solder in your formulation?  And is it lead free or Sn 63?

You know the deposited volume before reflow and can calculate the volume after the heating process.  Typical numbers for 5 mil thick stencils with Sn63 are 40% of original height, and I will admit it has been a long time since I have printed 8 mils thick.

My maximum print height limit for a 5 mil thick stencil is 6 mils which yields approximately a 2.4 bump after reflow.   It is never flat so be aware of this.

The wetting characteristics and shape of the pad can raise this number as high as 3 mils in my experience.

The true height of the bump will also depend on the flux characteristics (whether or not it completely runs off the molten solder or puddles on top.

If you have a component lead sitting on the paste, this will lower the thickness of the solder below the lead due to the solder wicking up onto the lead.

Good luck,

Phil


No Name <[log in to unmask]> wrote:
Hi,
Is there any formula to calculate the after reflow solder bump height?The
land size is 123*63mils with 1:1 stencil opening and using 8mils stencil.

regards
sumxp

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------


---------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
 Start your day with Yahoo! - make it your home page

ATOM RSS1 RSS2