Hi Sefika,

To my knowledge none of those files are necessarily Gerber files.  Visula does not require nor affix an extension to a Gerber file name in its default configuration.  Without a license of Visula, your may be to use the neutral file, .PAF extension, that is in CADIF format.  Some CAD/CAM vendors have the capability to convert the Visula neutral file to a different database, although that might cost $$$.   Another idea is to locate a board design shop that has a Visula license, and have them create the Gerbers for you.

Expert 3.5 is about 10 years old, but the .PCB or .PAF file should be readable by any Visula, version 3.5 or higher.

Regards,
Roger

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Sefika ÖZKAL
Sent: Friday, August 05, 2005 10:21 AM
To: [log in to unmask]
Subject: [TN] GERBER Format?

Dear Technetters,

I have a design which has file extensions as .ASC, .BXF, .CXF, .DAT, .FAF, .FUF, .HAF, .HBO, .HUF, .HXF, .IDX, .LAF, .LXF, .MAP, .NAF, .NXF, .PAF, .PCB, .PCG, .PCZ, .PEF, .SCA, .SCM.

When I open the files using NOTEPAD, in file with .LAF extension, it is written that Neutral Architecture File Created from VISULA PCB and in file with .NAF extension, it is written that Neutral Architecture File Created from Expert 3.5 Design Capture.

Although I do not have VISULA PCB and Expert 3.5 Design Capture tools, I need to open any gerber data of the design if it exists. I could not understand if any of the files whose extensions indicated above, are manufacturing files in GERBER format. If any of the files are manufacturing files, is it possible to open them using CAM350 or another gerber viewer? Or is there any other method to open the design using other CAD tools such as Board Station and Design Architect?

Thanks,

Regards

Sefika OZKAL
Design Engineer

ASELSAN INC. MGEO Division

Address     : Cankiri Yolu 7. Km
              Akyurt Ankara TURKEY
E-mail      : [log in to unmask]
Tel         : +90 312 84 75 300 Ext: 4698
Fax         : +90 312 84 75 320


Dikkat :
Bu elektronik posta mesajı kişiseldir. Eğer, gönderilmesi gereken kişi değilseniz lütfen göndericiyi bilgilendirip mesajı siliniz. Firmamıza gelen ve giden mesajlar virüs taramasından geçirilmekte, hukuki nedenlerle log kayıtları tutulmaktadır. Mesajdaki görüşler ve bakış açısı göndericiye ait olup Aselsan A.Ş. resmi görüşü olmak zorunda değildir.

Attention :
This e-mail message is private.
If you are not the intended recipient please delete the message and notify the sender. E-mails to and from the company are, monitored for virus protection and in accordance with lawful business practices.
Any views or opinions presented are solely those of the author and do not necessarily represent the views of Aselsan A.S.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2