Hi Steve,

For gold wire bonding, we use both full electrolytic and electroless
processes.  That is Electrolytic Ni/Electrolytic Au and Electroless
Ni/Electroless Au.  We haven't tried Electroless Ni/Electrolytic Au or
Electrolytic Ni/Electroless Au.  Not sure if that would ever come up.
Thickness, purity, and hardness are the key to good bondability with gold.

Glenn

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Steve Kelly
Sent: Thursday, August 25, 2005 6:31 AM
To: [log in to unmask]
Subject: [TN] Wire bondable gold


Good day to all,

Does it make any difference if the nickel underneath the wire bondable gold
is electroplated or electroless?  Thanks in advance. Steve Kelly



PFC Flexible Circuits Limited

Ph: (416) 750-8433

Fax: (416) 750-0016

Cell: (416) 577-8433

E-Mail: [log in to unmask]




---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2