We have been testing several material types for thermal integrity over
6x288C and IST testing.  The filled systems have been performing well
over the standard FR4 materials.  We are currently undergoing several
qualifications with OEMS on these materials in relation to specific
assembly processes.  I can share the specifics of the test programs and
models with you offline if you like.

The materials are more costly, but they are very similar visually to
their FR4 counterpart at the same manufacturer.  There are also some
manufacturing differences that you may notice if not maintaining a good
control of raw materials.  


Jeffrey Bush
Director, Quality Assurance and Technical Support

VERMONT CIRCUITS INCORPORATED
  76 Technology Drive - POB 1890
    Brattleboro, Vermont 05302
      Voice: 802.257.4571.21 Fax: 802.257.0011
           http://www.vtcircuits.com
 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Kane, Joseph E (US
SSA)
Sent: Thursday, August 18, 2005 10:27 AM
To: [log in to unmask]
Subject: [TN] New Resin System

New Phenolic cured epoxy resin systems are being qualified to
IPC-4101/24, 26, and 98 requirements.
Has anyone tested these new materials?  How do you know which material
you are really getting 
(new Phenolic or old DICY cured epoxy resins)?

Joe Kane
BAE SYSTEMS
Johnson City, NY

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2