Subject: | |
From: | |
Reply To: | |
Date: | Tue, 16 Aug 2005 16:04:42 -0400 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
This is not compliant and likely the soldermask adhesion will fail
testing in other areas and may increase in failure after reflow.
Jeffrey Bush
Director, Quality Assurance and Technical Support
VERMONT CIRCUITS INCORPORATED
76 Technology Drive - POB 1890
Brattleboro, Vermont 05302
Voice: 802.257.4571.21 Fax: 802.257.0011
http://www.vtcircuits.com
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Mumtaz Bora
Sent: Tuesday, August 16, 2005 3:12 PM
To: [log in to unmask]
Subject: [TN] Exposed Copper on PWB- Rejectable
Dear All,
I need a second opinion on the rejection of this exposed copper to
resolve
a line issue for IPC Class 2 . The defect images are posted on Steven
Gregory's website. Please go to page 2 and look for exposed Copper 1
and
Exposed copper 2. Thank-you Steven for the posting.Go
to:http://www.stevezeva.homestead.com
Thank-you
Mumtaz
D/ 252 - SMT Process and Component Quality
Bldg. V238E
Voice (858)-882-1967
Fax (858)-882-3126
Page (858)-635-1180
Cell: (858) -449-7054
email: [log in to unmask]
Kyocera-Wireless Corp.
10300, Campus Point Drive
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------
San Diego, Ca 92121,USA
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|