Your analysis is very close, but there are more concerns than just
drilling. There are several root causes evident in this report. First, yes
the drilling appears to be rather aggressive as evidenced by several areas
of "drill ripout" and copper wicking. This condition then appears to be
exaggerated by a slightly too aggressive hole clean that made the hole wall
even rougher. The brightener level of the copper plating bath then was not
correct. and the bath was unable to cover the glass bundles without
creating copper folds in the first plating process. The second plating
process then could not adequately cover these folds adequately (see photo
D1, top left). These plating folds are opening up causing your intermittent
opens, which after time will become permanent opens as thermal cycling
extends them around the circumference of the via. From my experience the
ranking of root causes is :
Brightener level in the copper plating bath
Drilling parameters
Hole clean process
This may even go back as far as the cure of the laminate material
The "cobblestone plating" is not rejectable by itself, but should lead to a
review for copper folds that have not been adequately covered with the
minimum amount of copper plating. This condition is a process indicator of
underlying concerns, and may or may not indicate failures.
Tom Kemp
Rockwell Collins
Collins Printed Circuits
Quality Manager
"Constantino J.
Gonzalez"
<[log in to unmask] To
T> [log in to unmask]
Sent by: cc
IPC-600-6012
<IPC-600-6012@ipc Subject
.org> [IPC-600-6012] Cobblestone"
appearance on via wall.
08/05/2005 08:54
AM
Please respond to
"(Combined Forum
of D-33a and
7-31a
Subcommittees)"
<IPC-600-6012@IPC
.ORG>
Hello here is Constantino J. Gonzalez from ACME, Inc. – Chairman of
IPC-A-610 Committee and one of my customers had a question.
Need your assistance on below ...
boards are failing for boot up / intermittent boot up with certain fallout
rate and Burn-in failures.
Affected location : U6 & U3 ( BGA) sent 2 board to 3rd party lab for a
failure analysis. ( report as attached)
-As you can see the solder joints looks good.
-There was no evidence of black pad .
- Double plating on via hole with "cobblestone" appearance on the 1st
plating.
-CU Wicking
I wondering why the hole wall structure has "Cobblestone" appearance?
Is this acceptable ??
We are unable to perform plating analysis as we don't have any more raw
cards.
Can Cu wicking, lead to boot up failure??
Is there any other analysis that can be perform ??
What is your opinion ??
Appreciate your help.
ACME F
Regards from your,
Official IPC MASTER INSTRUCTOR
Constantino J. González
President / Consultant Engineer
IPC-A-610 Committee Chairman
ACME, Inc.
AMERICAN-HISPANIC COMPANY
513 CLEVELAND STREET
RAPID CITY, SOUTH DAKOTA 57701
USA
E-mail: [log in to unmask]
Phone: 605-381-5963
Fax: 605-341-4261
(See attached file: Cobblestone.doc)(Embedded image moved to file:
pic07278.gif)
|
|
|