TechNetters,
I have re-read part of IPC/JEDEC J-STD-003A because of a question I was
asked. There was a section confusing one of our engineers and he asked
me to look a tit. I have and now I am confused!  So I am asking for your
help.

Section 4.1.2.1 says you can reset the floor life clock for MSL 2-4
parts by drying 5x an exposure time less than 12 hours.  Got it.

The note in the section seems to indicate that for times greater than 12
hours but less than the exposure limit of the component, the clock can
at least be stopped by drying as mentioned earlier in the section (dry
pack of < 10% RH cabinet)FOR MSL 2-3.

Section 4.1.2.2 says you can reset the floor life clock for MSL 5 & 5a
parts by drying 10x an exposure time less than 8 hours by dry bagging or
< 5% RH dry cabinet.

WHAT CAN YOU DO FOR MSL 4??!!

REGARDS,
Bev
RIM




---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential information, privileged material (including material protected by the solicitor-client or other applicable privileges), or constitute non-public information. Any use of this information by anyone other than the intended recipient is prohibited. If you have received this transmission in error, please immediately reply to the sender and delete this information from your system. Use, dissemination, distribution, or reproduction of this transmission by unintended recipients is not authorized and may be unlawful.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2