Heh heh,

Maybe the other Stephen sent it without telling you.......................

John

------------------------------------
Avanex
John Burke
Senior Manager RoHS Compliance
[log in to unmask]
40919 Encyclopedia Circle
Fremont
CA 94538
tel: 510 897 4250
fax: 510 979 0189
mobile: 510 676 6312
------------------------------------


-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Stephen Gregory
Sent: Thursday, July 21, 2005 10:56 AM
To: [log in to unmask]
Subject: Re: [TN] Soldermask inspection


Did this go out twice? I didn't send it twice...

They just had the email servers shut down over
lunch to do some work on them...

Let's see if this one goes out twice.


Kind regards,

-Steve Gregory-
Senior Process Engineer
LaBarge Incorporated
Tulsa, Oklahoma
(918) 459-2285
(918) 459-2350 FAX



|---------+---------------------------->
|         |           [log in to unmask]
|         |           com              |
|         |                            |
|         |           07/21/2005 12:42 |
|         |           PM               |
|         |                            |
|---------+---------------------------->

>---------------------------------------------------------------------------
-----------------------------------|
  |
|
  |       To:       TechNet E-Mail Forum <[log in to unmask]>@SMTP@Exchange,
Stephen R Gregory/LABARGE@LABARGE      |
  |       cc:
|
  |       Subject:  Re: [TN] Soldermask inspection
|

>---------------------------------------------------------------------------
-----------------------------------|




Huh! What are the odds that two guys with such similar names, working for
the same company, would give such similar answers? It's like Lou Gehrig
getting Lou Gehrig's disease....

-Chris



                       Stephen R Gregory
                       <[log in to unmask]        To:
[log in to unmask]
                       OM>                               cc:
                       Sent by: TechNet                  Subject:    Re:
[TN] Soldermask inspection
                       <[log in to unmask]>
                       07/21/2005 01:34 PM
                       Please respond to TechNet
                       E-Mail Forum; Please
                       respond to Stephen R
                       Gregory




                                Hi Cheryl!

                                IPC-600G, section 2.9.3.3 says that if a
soldermask dam (web) was supposed to be
                                there between a BGA and a via, it should be
there, otherwise it's nonconforming.

                                But it doesn't say how big the dam should
be...

                                Kind regards,

                                -Steve Gregory-
                                Senior Process Engineer
                                LaBarge Incorporated
                                Tulsa, Oklahoma
                                (918) 459-2285
                                (918) 459-2350 FAX





        Cheryl Johnson <[log in to unmask]>
                        Sent by: TechNet <[log in to unmask]>
                        07/21/2005 11:01 AM
                        Please respond to TechNet E-Mail Forum
<[log in to unmask]>; Please respond to Cheryl Johnson
<[log in to unmask]>

        To:     [log in to unmask]@SMTP@Exchange
        cc:     (bcc: Stephen R Gregory/LABARGE)
        Subject:        [TN] Soldermask inspection


                                Do you know if any spec exists defining
minimum soldermask webs
                                (particularly between vias and bga pads)?
                                Any inspection criteria?
                                Your help is appreciated.

                                Sincerely,

                                -----------------------------------

                                Cheryl Johnson, C.I.D.+

                                Manager

                                ExcelStor US Office, Engineering Services

                                Email: [log in to unmask]

                                Tel: (303) 684-7291

                                Fax: (303) 684-7268

                                Mobile: (303) 809-5815

                                -----------------------------------



---------------------------------------------------
                                Technet Mail List provided as a service by
IPC using LISTSERV 1.8e
                                To unsubscribe, send a message to
[log in to unmask] with following text in
                                the BODY (NOT the subject field): SIGNOFF
Technet
                                To temporarily halt or (re-start) delivery
of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
                                To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest
                                Search the archives of previous posts at:
http://listserv.ipc.org/archives
                                Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815

-----------------------------------------------------




__________________________________________________________________
                                This message may contain information that
is privileged and confidential to LaBarge, Inc.  It is for use only by the
individual or entity named above.  If you are not the intended recipient,
you may not copy, use or deliver this message to anyone.  In such event,
you should destroy the message and kindly notify the sender by reply
e-mail.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------









__________________________________________________________________
This message may contain information that is privileged and confidential to
LaBarge, Inc.  It is for use only by the individual or entity named above.
If you are not the intended recipient, you may not copy, use or deliver
this message to anyone.  In such event, you should destroy the message and
kindly notify the sender by reply e-mail.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2