Phil Nutting <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Phil Nutting <[log in to unmask]>
Date:
Tue, 28 Jun 2005 11:21:48 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (62 lines)
Ingemar,

We have uses HALT for initial design testing with HASS as follow-on
production testing.  It is not cheap, but we were able to find
weaknesses in the design.  IMO, by association, that should bring better
MTBF.  We perform these tests on our complete assembly.  That is where
we see the most interaction.

Another test we are performing is the shipping packaging test.  With the
completed working unit packed in it's special packaging materials, the
unit is placed on a shaker table for 1 hour and then dropped 12 times on
different faces, edges and corners.  This has been very useful.  An
electrically well designed unit is of no use if it can't get to the end
user without breaking.

Phil

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Ingemar Hernefjord
(KC/EMW)
Sent: Tuesday, June 28, 2005 10:54 AM
To: [log in to unmask]
Subject: [TN] HALT&HASS&MTBF

Anyone out there who use these and really got higher MTBF? And was it
worth the cost?
Not much discussed about in TN? Maybe wrong forum? 
Just in case someone was applying HALT&HASS.
My very q is this: can you apply this on whole equipment, or just on
single functions or
reduced areas because of too many parameters?
Cheers
Ingemar Hernefjord
Ericsson Microwave Systems

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2