Steve,
 
I happened to be looking at the two photos on page 2 of your web site showing No Nickel Corrosion and Nickel Corrosion. I don't remember who submitted them but I'm a little confused I thought they were cross sections of ENIG plating on a PCB.  However, the gold looks too thick to be ENIG.  There aren't micron marks on these images so I'm not sure my approximations are correct but if I assume 1 ounce copper then the electroless nickel appears to be about 270 microinches thick, which is a reasonable thickness for electroless nickel.  However, that would make the gold almost 50 microinches thick and that just doesn't make sense for ENIG.  Also, the gold seems to be as thick on the nickel that isn't corroded as it is on the nickel that is corroded.  I was hoping that whoever sent those images to you might read this posting and provide more information to clairify what these images are.

Regards, 
George 
George M. Wenger 
Reliability / FMA Engineer 
Base Station and Subsystems Group 
Andrew Corporation, 40 Technology Drive, Warren, NJ 07059 (908) 546-4531 [log in to unmask] 

 
------------------------------------------------------------------------------------------------
This message is for the designated recipient only and may
contain privileged, proprietary, or otherwise private information.  
If you have received it in error, please notify the sender
immediately and delete the original.  Any unauthorized use of
this email is prohibited.
------------------------------------------------------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
[mf2]

ATOM RSS1 RSS2