TECHNET Archives

June 2005

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Ingemar Hernefjord (KC/EMW)" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Ingemar Hernefjord (KC/EMW)
Date:
Wed, 22 Jun 2005 09:15:45 +0200
Content-Type:
text/plain
Parts/Attachments:
text/plain (168 lines)
Hi Gaby,

we do have 60% too, all mounting area is 50-60% in order to get low ESD risk. 
And still, most reels have no baking. Tantalum epoxy molded, resistors, ceramics,
SOTs, QFPs etc are exposed to the humidity in the assembly halls. And they are
soldered with no problems, as far as I know. Millions of them.

Exceptions: superBGAs and very large QFPs which are MS classed by the component
maker himself. These are stored in nitrogen cabinets or in plastic bags with 
dessicators. So, MS classed components are handled with care.

You did not tell us what components caused big trouble. Were they MS classed ?

Inge

-----Original Message-----
From: Gabriela Bogdan [mailto:[log in to unmask]]
Sent: den 21 juni 2005 16:40
To: TechNet E-Mail Forum; Ingemar Hernefjord (KC/EMW)
Subject: Re: [TN] Moisture sensitivity levels...


Inge, try to work in an environment with up to 60% humidity... we are baking 
and baking again...
If we miss we are in big trouble.
Gaby
----- Original Message ----- 
From: "Ingemar Hernefjord (KC/EMW)" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Tuesday, June 21, 2005 9:53 AM
Subject: Re: [TN] Moisture sensitivity levels...


> Steve,
> how come that you jumped high so sudden? Have you used some kind of 
> humidity issue filter
> all these years...he-he..cheating. There is humidity everywhere. Mother 
> nature infiltrates
> water vapour molecules everywhere she can. We learned that there is 
> humidity even on inside
> of glass feedtrues, water penetrates deeply into kovar packages, there is 
> water in the solder
> paste, every single "plastic" has a small amount of water on inside. Water 
> molecules are
> universal and unavoidable. We had a period of humidity hysteria, digged 
> deeply into the
> mystery of water penetration mechanisms by means of proffessors and 
> doctors, had seminars,
> and the learned painted scaring scenarios about all bad things that could 
> occur due to water in
> the material. We spent a lot of money on residue gas analysis and made 
> lots of MIL STD
> tests and so on. The years pass and behold, a miracle: there has been no 
> catastroph. Some
> few reports have been noticed, but the equipments spread all over the 
> globe seem to work,
> and mounting seems to go on rather free from incidents despite there is 
> water in every
> single component. So, I wonder if all anti-humidity countermeasures are 
> proportional to the
> very few failures that occur due to water.
>
> My thoughts do not necesserarily represent the general opinion here, I'm 
> just curious about
> the mystery of water content and others experience. Is humidity a severe 
> problem today?
> Can anyone give example?
>
> (I don't include water that penetrates into packages from the surrounding 
> during field use,
> but just point at built-in humidity in parts before and during assembly.)
>
> Ingemar Hernefjord
> Ericsson Microwave Systems
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]]On Behalf Of Stephen Gregory
> Sent: den 20 juni 2005 17:26
> To: [log in to unmask]
> Subject: [TN] Moisture sensitivity levels...
>
>
> Good mornin' all!
>
> I hope all you Dads out there had a wonderful Fathers Day!
>
> As I posted about a week or so ago, we're getting our stockroom
> personnel to really focus on component moisture sensitivity levels.
>
> But now I'm starting to get a little confused about how components
> are generally classified with their respective MSL ratings.
>
> I've always thought that it had to do with component body size and
> thickness,
> but now I'm finding out that it doesn't necessarily.
>
> My stockroom clerk showed me an IDT SOJ28 that came in sealed with a MSL 3
> rating that we now have in our dry box because the package was opened.
>
> We have some Cypress SOJ28's and SOJ24's that are on reels that are not in
> original packaging, so I called Cypress and asked what the MSL rating is
> for the
> two part numbers and they are a MSL 1. Cypress gave me a link to the SRAM
> Qualification Report that states that.
>
> Now my stockroom clerk brought me some Vishay tantalum caps that have
> a MSL 2a rating label on them, and they are TNTC's. This is THE FIRST time
> I
> have ever seen a MSL label on a tantalum capacitor.
>
> Are these ratings based on qualification reports? Or can one look at the
> size and
> thickness of the part to base how you will handle it?
>
> Kind regards,
>
> -Steve Gregory-
> Senior Process Engineer
> LaBarge Incorporated
> Tulsa, Oklahoma
> (918) 459-2285
> (918) 459-2350 FAX
> __________________________________________________________________
> This message may contain information that is privileged and confidential 
> to
> LaBarge, Inc.  It is for use only by the individual or entity named above.
> If you are not the intended recipient, you may not copy, use or deliver
> this message to anyone.  In such event, you should destroy the message and
> kindly notify the sender by reply e-mail.
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to 
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to 
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
> for additional information, or contact Keach Sasamori at [log in to unmask] or 
> 847-615-7100 ext.2815
> -----------------------------------------------------
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to 
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to 
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 
> for additional information, or contact Keach Sasamori at [log in to unmask] or 
> 847-615-7100 ext.2815
> ----------------------------------------------------- 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2