Jerry,

You missed the stream of e-mails on Tant cap failures and voltage...

You should be using 50 volt caps....
You will find a fairly high failure rate on 35V caps run at 25V input where
there is a possibility power rail bounce...

You need to voltage and temp de-rate the Tants...

I use the AVX reference specifications...

Paul

Paul Edwards
Process Engineering
[log in to unmask]
Tel: 408-433-4700
FAX: 408-433-9988
Surface Art Engineering
81Bonaventura Dr.
San Jose, CA 95134
DUNS: 944740570
CAGE/NCAGE: 1XZ48

-----Original Message-----
From: McGlaughlin, Jeffrey A [mailto:[log in to unmask]]
Sent: Wednesday, May 04, 2005 11:01 AM
To: [log in to unmask]
Subject: [TN] Failed Tantalum Capacitors

We have recently had a rash of tantalum capacitor failures, where the
capacitors on an input filter fail to a high impedance state. These are
35V Kemet T491X series cap's, and the failure have been found at first
power up at 24 volts. Is there any known issues with these cap's? Are we
doing something wrong, like handling, design, other?

Thanks In Advance,

Jeffrey A McGlaughlin, CID
Engineering Designer
Battelle Memorial Institute
Columbus Ohio
http://www.battelle.org
[log in to unmask]

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2