Subject: | |
From: | |
Reply To: | |
Date: | Wed, 25 May 2005 00:16:05 +0100 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Sherif
First off, Wetting balance Gage R&R is under preparation through the latest
IPC RR test program.
Ionic contamination testers would not suit Gage R&R due to the test
parameters not providing a constant defined start condition.
As regards the MUST manufacturer - I am he! Who did you ask for this
information so that I might address that problem?
--
Regards Graham Naisbitt
[log in to unmask]
NEW ADDRESS FROM 31ST MAY 2005:
CONCOAT SYSTEMS LIMITED
Unit B2, Armstrong Way
Southwood Business Park
Farnborough GU14 0NR
Phone: +44 (0)1252 521500
Fax: +44 (0)1252 521112
CONCOAT - Engineering Reliability in Electronics
CONCOAT SYSTEMS - Measuring Reliability in Electronics
A British Manufacturer
www.concoat.co.uk & www.concoatsystems.com
Cell: 079 6858 2121
On 24/5/05 22:41, "Sherif Refaat" <[log in to unmask]> wrote:
> Hi All,
>
> Is "R&R" evaluation applicable to "Wetting Balance" and "Omegameter"?
>
> I'm trying to convince my customer that the R&R evaluation is applicable to
> gauges only and not equipment like "Wetting Balance" and "Omegameter", where
> the results are printed out and the operator does not read a scale to get
> the result. I mentioned that proper calibration is enough to ensure accurate
> readings, but the customer would like my company to use R&R evaluation.
>
> I have tried to get information from the manufacturer of the "MUST" wetting
> balance, who took over from "Multicore", but so far there is no response.
>
> Sherif Refaat, Eng.
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV 1.8e
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt or (re-start) delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search the archives of previous posts at: http://listserv.ipc.org/archives
> Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
> additional information, or contact Keach Sasamori at [log in to unmask] or
> 847-615-7100 ext.2815
> -----------------------------------------------------
>
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|