Hi George,
What about the cadmium levels? Regards Steve Kelly

PFC Flexible Circuits Limited
Ph: (416) 750-8433
Fax: (416) 750-0016
Cell: (416) 577-8433
E-Mail: [log in to unmask]

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of George Milad
Sent: Friday, May 20, 2005 10:35 AM
To: [log in to unmask]
Subject: Re: [TN] ENIG Board finish and RoHS

RoHS
(Restriction of Use of  Hazardous Substances)
    *   Initially issued in 2003 by  the European Commission.
    *   Directs the European Union to  enact the Hazardous Substance ban by
July 1,  2006
    *   Max allowed concentrations of  the materials:
Cadmium  0.01%  (100  ppm)
Lead 0.1% (1000  ppm)
Mercury 0.1%  (1000 ppm)
Hex Chrome 0.1%  (1000 ppm)
PBB  0.1%
PBDE  0.1%

Lead is used as a stabilizer in most electroless nickel baths  formulations.
The concentrations of lead are well below the maximum allowable
concentrations, in the bath or in the deposit.

When RoHS are enacted the supplier will be restricted from  intentionally
adding lead to his formulation even if it is below the specified  limits.

Suppliers are well aware of the approaching date. Most suppliers  already
have lead free formulations available. Check with your individual  supplier,
to
determine when and if you need to make the  change.



Best  regards

George Milad
[log in to unmask]
National Accounts Manager  for Technology
Uyemura International Corporation
Technical Center
240  Town LIne Rd
Southington CT 06489
(516) 901 3874 (mobile)
(860)  793-4011 (office)
(860) 793-4020 (fax)

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2