Good Mornin' all you Techno's!

Gonna be heading to San Diego this afternoon to visit a potential
customer, hope the weather is as nice as it usually is out there.

I have a question about ODB++ files. My stencil vendor called me
a few days ago after I had sent them a ODB++ file to get the stencil
made for a board. They said for some reason things didn't look right
at  a few locations...specifically at some TO 252/268 locations.

The two pads for the leads were overlaping the one big area for the
base of the footprint. I didn't have an actual board yet, so I couldn't
verify the dimensions of everything.

I have two different viewers here that are capable of viewing ODB++
files, Autoview SolidModel by Cimmetry Systems, and a Valor Universal
Viewer, of course by Valor.

I discovered that things can look different depending on what you use
to view ODB++ files. Take a look at; "Autoview SolidModel" and Valor
Universal Viewer" on my page at; http://www.stevezeva.homestead.com

Look at the way the footprint looks for Q2, Q3, Q4, and Q5.

I just got the fab yesterday afternoon and confirmed that the image that I
see with the Valor Universal Viewer is correct. Why does different software
display ODB++ files so differently?

Kind regards,

-Steve Gregory-
Senior Process Engineer
LaBarge Incorporated
Tulsa, Oklahoma
(918) 459-2285
(918) 459-2350 FAX
__________________________________________________________________
This message may contain information that is privileged and confidential to
LaBarge, Inc.  It is for use only by the individual or entity named above.
If you are not the intended recipient, you may not copy, use or deliver
this message to anyone.  In such event, you should destroy the message and
kindly notify the sender by reply e-mail.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2