Hi Lon,
You should not have an issue as long as you use a polyimide base and a
polyimide covercoat - not a flexible soldermask. The part can take one
crease but if you open it and close the flex , it will probably fail. You
obviously cannot bend through the nickel/gold. If you want to be extra sure
build it as an adhesiveless with a thinner kapton covercoat. Good Luck.
Steve Kelly
PFC Flexible Circuits Limited
Ph: (416) 750-8433
Fax: (416) 750-0016
Cell: (416) 577-8433
E-Mail: [log in to unmask]
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Lon Weffers
Sent: Thursday, May 12, 2005 7:13 AM
To: [log in to unmask]
Subject: [TN] Bending flex 90 deg
Dear Technetters,
What type of flex can I best use to bend 90 degrees?
Our custormer wants to glue the flex inside a metal box. The radius in the
corners should be as small as possible. (nearly zero)
Copper thickness about 30micron, goldfinish.The flex is designed with a lot
of parallel tracks, single sided.
Thanks in advance
Lon Weffers
Matas Electronics
The Netherlands
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|