Most of the answers given are from PCB manufacturers, where ESD is not a consideration. What gloves hould be used in the assembly house before and after the reflow?
Regards
Ofer Cohen
Seabridge
A Siemens company
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Kaye Clayo
> Sent: Wednesday, May 11, 2005 19:53
> To: [log in to unmask]
> Subject: [TN] Gloves for handling Immersion Silver finished boards
>
> Hi Technet,
>
> Can anyone share what type of glove should be used when
> handling immersion silver boards?
>
> If the immersion silver manufacturers say that rubber bands
> are detrimental to the IAg finish, would latex gloves be bad also?
> Are cotton gloves the answer? Is there another type of glove
> that is better?
>
> I have not been able to identify exactly what glove to use.
> Or, maybe the type of glove is not even an issue?
>
> Thanks in advance,
>
> Kaye Clayo
>
> CONFIDENTIALITY NOTE: This message is intended only for the
> use of the individual or entity to which it is addressed and
> may contain information that is privileged, confidential, and
> exempt from disclosure under applicable law. If the reader of
> this notice is not the intended recipient, you are hereby
> notified that any dissemination, distribution or copying of
> this communication is strictly prohibited. If you have
> received this communication in error, please notify the
> sender immediately.
>
>
>
> ______________________________________________________________
> _______________
> Scanned by IBM Email Security Management Services powered by
> MessageLabs. For more information please visit
> http://www.ers.ibm.com
> ______________________________________________________________
> _______________
>
> ---------------------------------------------------
> Technet Mail List provided as a service by IPC using LISTSERV
> 1.8e To unsubscribe, send a message to [log in to unmask] with
> following text in the BODY (NOT the subject field): SIGNOFF
> Technet To temporarily halt or (re-start) delivery of Technet
> send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
> To receive ONE mailing per day of all the posts: send e-mail
> to [log in to unmask]: SET Technet Digest Search the archives
> of previous posts at: http://listserv.ipc.org/archives Please
> visit IPC web site
> http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
> additional information, or contact Keach Sasamori at
> [log in to unmask] or 847-615-7100 ext.2815
> -----------------------------------------------------
>
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|