TECHNET Archives

May 2005

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Colin McVean <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Colin McVean <[log in to unmask]>
Date:
Tue, 3 May 2005 17:01:35 +0100
Content-Type:
text/plain
Parts/Attachments:
text/plain (73 lines)
This looks like a case of over-plating, (nodules on pads) where the
current density is either too high for the board in question, or they
are isolated via pads, which will incur a high CD. Remedies for this are
low CD and/or thieving. Other possibility is that they have been in the
plating tanks too long, but if the CD was correct, then all that should
happen is that the plating just gets thicker and stays smooth.
Subsequent etching will show an overhang, which could trap dry film
resist.

Colin McVean
Production Manager
Artetch Circuits Limited
Tel: 01903 725365

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Al Onderick
Sent: 03 May 2005 16:40
To: [log in to unmask]
Subject: [TN] Via contamination

Greetings Tech netters,



            In the past we've had problems with tented vias not
completely
tenting and trapping liquid.  The liquid would boil and find its way to
the surface of the board.



While this looks similar these vias were not tented.





http://www.texas-gold.org/PCB/



Al Onderick

National Instruments


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2