Bev Christian <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Bev Christian <[log in to unmask]>
Date:
Tue, 10 May 2005 09:14:56 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (189 lines)
Cheryl,
I have been reading the good responses you have received and have been
giving this some more thought.  I would say cross-sectioning is pretty
well a must.  The reason I asked where the cracks were located was
because (English?) I am wondering if you were talking about pad lifting
or actual cracks in the joints.  That's also why I asked about solder
composition.  Also, those holes where you only have 50% hole fill may be
in violation of 610, if you can't see the hole fill.  When you say "the
wetting looks weak", are you meaning the solder wetting angle is poor or
what?  I agree with the assessment of yourself and others that getting
enough heat to this board may be an issue.  No magic answers but ...

Regards,
Bev
RIM

-----Original Message-----
From: [log in to unmask] [mailto:[log in to unmask]] 
Sent: May 9, 2005 5:09 PM
To: Bev Christian
Cc: TechNet E-Mail Forum
Subject: RE: [TN] Suggested failure analysis technique?

You're right. I should refer to them as "cracks" rather than fractures.
We
haven't found any mechanical stress  in the final assembly process that
can
force a fracture (yet anyway) .

The cracks are found at the interface between the lead and the solder.
They
are typically about 1/4" of the joint circumference.
This is a standard 63/37 tin lead solder process on FR4 boards.
Pot temp is set at 240 C.
The connectors are BNC style with 4 outer ground pins (nickel plated)
and 1
center signal pin (gold plated).
The board is processed through the wave in a fixture exposing a slot
about
1 inch wide and 4 inches long.
The connectors run along the edge of the board.
The solder pot is monitored quarterly and is currently in specification.

The ground pins are directly connected to internal planes (no thermal
relief).
Hole fill on the ground pins is at 50%. Hole fill on the signal pin is
about 90%.
The wetting looks weak and it is difficult to deliver enough heat to
make a
great joint. I currently have no unprocessed boards to work with.

Thanks!

Cheryl Tulkoff




 

             "Bev Christian"

             <[log in to unmask]

             om>
To 
                                       "TechNet E-Mail Forum"

             05/09/2005 03:57          <[log in to unmask]>, "Cheryl
Tulkoff" 
             PM                        <[log in to unmask]>

 
cc 
 

 
Subject 
                                       RE: [TN] Suggested failure
analysis 
                                       technique?

 

 

 

 

 

 





Cheryl,
You are short on details.

How do you know they are fractures?

Are your boards FR4, ceramic CEM?

What temp is your pot?

What solder are you talking about SnPb, lead free with bismuth in it?

Where exactly on the joints are the possible anomalies?

Bev
RIM



-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Cheryl Tulkoff
Sent: May 9, 2005 4:46 PM
To: [log in to unmask]
Subject: [TN] Suggested failure analysis technique?

I have a large lot of circuit boards where about 20% have small,
hairline
solder fractures around some wave soldered PTH connector joints. We're
working on root cause analysis to prevent it from happening and
repairing
the boards which have failed inspection. But, we're tying to figure out
what to do with the boards that have passed the inspection but may be at
risk. Quick and dirty tests have been unable to create fractures on
these
joints and they pass visual criteria. Are there any quantitative tests
that could be performed on a sample to verify solder joint integrity? We
don't hae any historical data for comparison.

Thanks! Cheryl

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------




---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential
information, privileged material (including material protected by the
solicitor-client or other applicable privileges), or constitute
non-public
information. Any use of this information by anyone other than the
intended
recipient is prohibited. If you have received this transmission in
error,
please immediately reply to the sender and delete this information from
your system. Use, dissemination, distribution, or reproduction of this
transmission by unintended recipients is not authorized and may be
unlawful.






---------------------------------------------------------------------
This transmission (including any attachments) may contain confidential information, privileged material (including material protected by the solicitor-client or other applicable privileges), or constitute non-public information. Any use of this information by anyone other than the intended recipient is prohibited. If you have received this transmission in error, please immediately reply to the sender and delete this information from your system. Use, dissemination, distribution, or reproduction of this transmission by unintended recipients is not authorized and may be unlawful.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2