Degradation of FR406 begins ~ 230 C and will not withstand TC above this
very well. I suggest trying this material as a control with an
experimental lot of a filled material like IS415 is you like Isola. You
may find that FR408 works well for you application as well - it has a
higher Td than FR406 and is slightly more in cost. Testing is the key
which should include some package analysis after the TC processes - DSC,
TMA, TGA, DMA, etc.
Jeffrey Bush
Director, Quality Assurance and Technical Support
VERMONT CIRCUITS INCORPORATED
76 Technology Drive - POB 1890
Brattleboro, Vermont 05302
Voice: 802.257.4571.21 Fax: 802.257.0011
http://www.vtcircuits.com
-----Original Message-----
From: Kerry McMullen [mailto:[log in to unmask]]
Sent: Wednesday, May 11, 2005 1:03 PM
To: [log in to unmask]
Subject: [TN] FR406 Tg 175 Degrees C - Lead Free Processing
Hi TechNetters
Can I use FR406 175 Degrees C laminate during a lead free assembly
process
where the reflow temp will be around 260 Degrees C. ?
The boards will be ENIG. Any disadvantages.
I know there was a thread, but I can't find it.
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|