Technetters,
Where can I find the requirements for the 0402 pad layout. I
have checked 7351 and cannot locate the criteria.
Judy Brown
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Le Thanh Tung
Sent: Tuesday, May 10, 2005 5:39 PM
To: [log in to unmask]
Subject: Re: [TN] Tombstone
Following is one of reasons cause Tombstone:
- Vertial shifted part: Mounting condition is NG
- Not same solder paste volume at two sides of part: Printing
condition
is NG.
- Temperature at two electrodes of part is different: when PCBA
going
through reflow machine, one electrode
of part will be heated and smell first -- > tombstone
Best regard.
----- Original Message -----
From: "Suganthi" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Tuesday, May 10, 2005 2:51 PM
Subject: [TN] Tombstone
Dear All,
What is called Tombstone effect ,please explain me , and tell me how to
overcome this problem..
Thanks and Regards
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask]
or
847-615-7100 ext.2815
-----------------------------------------------------
Suganthi
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|