TECHNET Archives

April 2005

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Anthony Gorga <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Anthony Gorga <[log in to unmask]>
Date:
Fri, 1 Apr 2005 10:36:19 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (240 lines)
These two recent postings almost seem to shed a little bit of light to
the end of this long tunnel. I have been watching these postings for 4
months now looking for information more directed to my company's
product. We are a manufacturer of microwave frequency cable assemblies.
The better part of our customer base does not want to hear of a change
in our solder compound, good old Sn63/Pb37. We do however have a client
base in Europe and Asia and must satisfy their market needs. Does anyone
have information more directed to our industry rather PCB manufacturing?

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Paula Esty
Sent: Thursday, March 31, 2005 3:04 PM
To: [log in to unmask]
Subject: Re: [TN] Almost RoHS compliant??


Hi -  I hope this helps,
RoHS Compliance:  The European Commission will formally adopt the
following waivers (exemptions) some time next month (April):


The New Waivers (Exemptions) will be:

- Lead used in compliance-pin VHDM (very high density medium) connector
systems

- Lead as coating material for thermal conduction module C-ring

- Lead and cadmium in optical and filter glass

- Lead in solders consisting of more than two elements for the
connection between the pins and the package of microprocessors with a
lead content of more than 85% in proportion to tin-lead content -
exemption until 2010

- Lead in high melting temperature solders (I,e, tin-lead solder alloys
containing more than 85% lead) and any lower melting temperature solder
required to be used with a high melting temperature solder to complete a
viable electrical connection

- Lead in solders to complete a viable electrical connection internal to
certain integrated circuit packages (Flip Chips) - exemption until 2010.


Best regards,
Paula Esty
Senior Environmental Systems Specialist
Capaccio Environmental Engineering, Inc.
Voice: (508) 970-0033 ext. 28
Fax: (508) 970-0028
www.capaccio.com * www.iso14000.com

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Stephen Gregory
Sent: Thursday, March 31, 2005 2:56 PM
To: [log in to unmask]
Subject: Re: [TN] Almost RoHS compliant??

Hi Dave!

This is what I found:





      The following changes and additions to the list of exemptions
within
      the RoHS Annex have been adopted and should enter the official
      Journal in February or March.


      Paragraph 7 previously read:


      "7. Lead in high melting temperature type solders (i.e. tin-lead
      solder alloys containing more than 85 % lead),
      lead in solders for servers, storage and storage array systems
      (exemption granted until 2010),lead in solders for network
      infrastructure equipment for switching, signalling, transmission
as
      well as network management for telecommunication,lead in
electronic
      ceramic parts (e.g. piezoelectronic devices)."


      This will be replaced with:


      "7. Lead based alloys containing 85% by weight or more lead,lead
in
      solders for servers, storage and storage array systems network
      infrastructure equipment for switching, signalling, transmission
as
      well as network management for telecommunications,lead in
electronic
      ceramic parts (e.g. piezoelectronic devices)."






Kind regards,

-Steve Gregory-
Senior Process Engineer
LaBarge Incorporated
Tulsa, Oklahoma
(918) 459-2285
(918) 459-2350 FAX


|---------+---------------------------->
|         |           Dave Seymour     |
|         |           <dave.seymour@CAT|
|         |           APULT.COM>       |
|         |           Sent by: TechNet |
|         |           <[log in to unmask]>|
|         |                            |
|         |                            |
|         |           03/31/2005 01:29 |
|         |           PM               |
|         |           Please respond to|
|         |           TechNet E-Mail   |
|         |           Forum; Please    |
|         |           respond to Dave  |
|         |           Seymour          |
|         |                            |
|---------+---------------------------->

>-----------------------------------------------------------------------
>----
-----------------------------------|
  |
|
  |       To:       [log in to unmask]
|
  |       cc:
|
  |       Subject:  [TN] Almost RoHS compliant??
|

>-----------------------------------------------------------------------
>----
-----------------------------------|




<>
A IC vendor, when questioned about a particular BGA part we are using
made the following statement:

"This BGA is almost RoHS compliant today. It uses 90/10 Pb/Sn spheres
and bumps which meet RoHS exemption requirements. However, to be fully
RoHS compliant, we must switch from high-Pb to no-Pb capacitor attach.
This <>may happen in ~2006. There are no plans to further modify the
this BGA package."

Question #1 - Is there an exemption to the RoHS rules with reguards to
high temp lead  solders?

--
Dave Seymour, CID+
Catapult Communications Inc.
800 Perimeter Park Dr, Suite A
Morrisville, NC 27560

Direct: (919)653-4249
Main: (919)653-4180
Fax: (919)653-4297

[log in to unmask]



---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask]
or 847-615-7100 ext.2815
-----------------------------------------------------




__________________________________________________________________
This message may contain information that is privileged and confidential
to LaBarge, Inc.  It is for use only by the individual or entity named
above. If you are not the intended recipient, you may not copy, use or
deliver this message to anyone.  In such event, you should destroy the
message and kindly notify the sender by reply e-mail.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask]
or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the
posts: send e-mail to [log in to unmask]: SET Technet Digest Search the
archives of previous posts at: http://listserv.ipc.org/archives Please
visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for
additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2