It sounds so good.. 

Unfortunately, so little companies are even conscious of the advantage of
the IPC-356.. and if the CAD software does not yet automatically supply it,
please request it.

Any idea of the percentage of PCB orders that are using IPC-356 ???

Can PCB manufacturers give an idea of the percentage of jobs they get with
it???

I seen Electrically Tested PCB's that were missing an inner layer... because
they used the Golden board approach... 


Very Best regards
Rol@nd
 
www.PCBspecialist.com
T +41-22-880-0405 F +41-22-880-0409 Mob +41-79-203-3723
 

-----Message d'origine-----
De : TechNet [mailto:[log in to unmask]] De la part de Dave Seymour
Envoyé : mercredi, 6. avril 2005 15:57
À : [log in to unmask]
Objet : Re: [TN] Golden Board Electrical test

To add Marsal response.

The golden board goes through shorts and opens test,
visual QC and then passed. This board the becomes the
reference that all other boards are then check by.

However, this not an electrical netlist test.
If the generated Gerber artwork had an error during output at
the design phase, the artwork produced may not match the intended
schematic.

At this point all boards match each other and are declared "good",
But, the boards don't match the schematic.

This is the reason for the "IPC-356" netlist being included with all
jobs going to fabrication. All designs that leave our shop must have
an extract IPC-356 netlist for the fab shop to verify artwork shipped.

Hope this helps.
dave




Marsal Tampubolon wrote:

>Hi  Suganthi..
>In  other   words,  golden  board    also   call   as    KGB
>(Known Good board ). Sometimes    also   call    as   reference
>board.   Meaning   it  is  the   sample   board   that    being
>pass  test   if  there  is  electrical  test     conducted   or
>pass   visual   test.  This   board   will   using    for   set
>up  tester   before   run  to  mass   production  test  or  during
>comparison    for   troubleshoot   board  defect   from  the  same
>model.
>
>****************************************************
>Regards...
>Marsal GM Tampubolon.
>
>
>|---------+---------------------------->
>|         |           Suganthi         |
>|         |           <suganthi@CG-CORE|
>|         |           EL.COM>          |
>|         |           Sent by: TechNet |
>|         |           <[log in to unmask]>|
>|         |                            |
>|         |                            |
>|         |           06-04-05 04:30 PM|
>|         |           Please respond to|
>|         |           Suganthi         |
>|         |                            |
>|---------+---------------------------->
>
>---------------------------------------------------------------------------
-------------------|
>  |
|
>  |       To:       [log in to unmask]
|
>  |       cc:
|
>  |       Subject:  [TN] Golden Board Electrical test
|
>
>---------------------------------------------------------------------------
-------------------|
>
>
>
>
>
>
>Dear All,
>
>
>
>    please explain me what is "Golden Board" electrical test
>
>
>
>Thanks and Regards
>
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 1.8e
>To unsubscribe, send a message to [log in to unmask] with following
>text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail
>to [log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to
>[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at:
>http://listserv.ipc.org/archives
>Please visit IPC web site
>http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
>information, or contact Keach Sasamori at [log in to unmask] or
>847-615-7100 ext.2815
>-----------------------------------------------------
>Sug
>
>---------------------------------------------------
>Technet Mail List provided as a service by IPC using LISTSERV 1.8e
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
>To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
>Search the archives of previous posts at: http://listserv.ipc.org/archives
>Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
>-----------------------------------------------------
>
>
>
>

--
Dave Seymour, CID+
Catapult Communications Inc.
800 Perimeter Park Dr, Suite A
Morrisville, NC 27560

Direct: (919)653-4249
Main: (919)653-4180
Fax: (919)653-4297

[log in to unmask]

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2