You will need to hold the PCB at the recommend cure temperature for that
material for a period of time dependent on the cure state of the
package.  Standard FR4 (140 Tg) is generally cured at 350-360 F for 45
minutes minimum.  The problem with this temperature on a completed PCB
is the finish.  Solder will begin to move at 320 F and other finishes
like IT and IS will be adversely affected for later wetting.  ENIG
should survive this cycle and may need to be cleaned prior to soldering
to remove any oxides.  

I would recommend a 300 F bake for 1 hour to improve the Tg to a nominal
performance range.  Any temperature above the epoxies Tg will cure the
material with time being the variable.  

What issues are your seeing that leads you to question the cure?
  
Jeffrey Bush
Director, Quality Assurance and Technical Support

VERMONT CIRCUITS INCORPORATED
  76 Technology Drive - POB 1890
    Brattleboro, Vermont 05302
      Voice: 802.257.4571.21 Fax: 802.257.0011
           http://www.vtcircuits.com
 

-----Original Message-----
From: Kaye Clayo [mailto:[log in to unmask]] 
Sent: Wednesday, April 27, 2005 3:10 PM
To: [log in to unmask]
Subject: [TN] How to Bake FR4 Boards

Dear Technet:

Can someone tell me what temperature and duration
we should bake some unpopulated FR4 (HASL) boards?

We are attempting an experiment to see if we can "bake" a
potential problem out of certain boards, but we don't know
what the baking temperature / time should be.  The potential
problem we are looking to bake out is under cured laminate
which could be causing a hook problem.

Please help.

Kaye


CONFIDENTIALITY NOTE: This message is intended only for the use of the
individual or entity to which it is addressed and may contain
information that is privileged, confidential, and exempt from disclosure
under applicable law. If the reader of this notice is not the intended
recipient, you are hereby notified that any dissemination, distribution
or copying of this communication is strictly prohibited. If you have
received this communication in error, please notify the sender
immediately.



________________________________________________________________________
_____
Scanned by IBM Email Security Management Services powered by
MessageLabs. For more information please visit http://www.ers.ibm.com
________________________________________________________________________
_____

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2