Subject: | |
From: | |
Reply To: | |
Date: | Fri, 1 Apr 2005 14:45:48 -0500 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
The current specification for this material would be - IPC-4101 L21 0200
C1/C1 AB - bow and twist is no longer a problem for laminate
manufacturers.
Jeffrey Bush
Director, Quality Assurance and Technical Support
VERMONT CIRCUITS INCORPORATED
76 Technology Drive - POB 1890
Brattleboro, Vermont 05302
Voice: 802.257.4571.21 Fax: 802.257.0011
http://www.vtcircuits.com
-----Original Message-----
From: John Parsons [mailto:[log in to unmask]]
Sent: Friday, April 01, 2005 2:12 PM
To: [log in to unmask]
Subject: [TN] MIL-S-13949 Cross Reference
I have a customer spec'ing the following FL-GF020C1/1BIIA
OK, so I know(?) that this is a MIL-S-13949 spec. I don't have an old
copy
so have done the requisite "Google" and Technet Archive search in an
attempt
to understand this so I can cross it to IPC-4101. I could use some
help.
1. FL = Flexible laminate correct? TL = thin laminate?? What is
the
difference in construction for a given dielectric thickness (020)?
2. "B" after C1/1 still refers to thickness tolerance? Does it
equate
to "B" in 4101?
3. What is "IIA" after the "B"?
4. Anyone want to provide the exact 4101 equivalent callout for the
above spec?
Happy Friday!
John Parsons
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|