Steve,
If it can't take the heat of pre-tinning how are you going to solder it?
I assume only the tabs are soldered and need tinning.  With the construction
seen in your photo I suggest 2 quick dips in a solder pot with a short
cooling period in between.  This should not be a problem to a ceramic part
like that.

> Rainer G. Blomberg
> Honeywell -Space Systems Clearwater
> Staff Production Engineer
(727) 539-5534



-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Stephen Gregory
Sent: Wednesday, April 13, 2005 3:51 PM
To: [log in to unmask]
Subject: Re: [TN] Tinning of Bipolar Transistor

Hi Ramon!

The J-STD only allows gold on PTH components if it is below a certain
thickness. But it states that you must remove 95% of the gold from the
solderable surfaces regardless of the thickness.

I'm trying to track down somebody that I can speak with who made these
devices, to learn what the solder alloy is that connects the top half of the
part...it's probably high temp solder.

I don't want to take a chance with these little guys by experimenting,
because they are customer supplied material. The reason they are customer
supplied is because they did a lifetime buy of them...once they're gone,
they're gone...there is no replacing them.

Kind regards,

-Steve Gregory-
Senior Process Engineer
LaBarge Incorporated
Tulsa, Oklahoma
(918) 459-2285
(918) 459-2350 FAX


|---------+---------------------------->
|         |           "Dehoyos, Ramon" |
|         |           <ramon.dehoyos@ng|
|         |           c.com>           |
|         |                            |
|         |           04/13/2005 02:21 |
|         |           PM               |
|         |                            |
|---------+---------------------------->

>---------------------------------------------------------------------------
-----------------------------------|
  |
|
  |       To:       "TechNet E-Mail Forum" <[log in to unmask]>,
<[log in to unmask]>                      |
  |       cc:
|
  |       Subject:  RE: [TN] Tinning of Bipolar Transistor
|

>---------------------------------------------------------------------------
-----------------------------------|






             Hi Steve:
                                     It should be no problem. The package is
made of what appears ceramic. I would still do one and check it under the
microscope just in case. I talked a while back to a lead plating company and
they let me know, that the plating thickness, that gold flashing (that is
the gold plating process used on leads) produces, is less than the 98
millionths of an inch that  is allowable by J-STD-001. In many cases it is
not even necessary to remove the gold. Many people do it just in case.
             Regards,
             Ramon

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Stephen Gregory
Sent: Wednesday, April 13, 2005 1:50 PM
To: [log in to unmask]
Subject: [TN] Tinning of Bipolar Transistor


Hi All!

We've got this Bipolar Microwave Transistor that I've just seen for the
first time, and I was asked if this part needs tinning because of the gold
plating.

I know what the J-STD says, but looking at the construction of the part, I
don't know if the part can withstand the heat of a tinning operation.

Take a look at "Bipolar Transistor" on my web page at:

http://www.stevezeva.homestead.com

I've tried to track down a datasheet, but can't seem to find one. The top of
the part is marked; "TRW 54601" and just below that, there's a "C86"
marked there.

The part may be very robust, and I have nothing to worry about. But because
this is the first time I've seen something like this, I thought I'd ask the
experts out there...

Kind regards,

-Steve Gregory-
Senior Process Engineer
LaBarge Incorporated
Tulsa, Oklahoma
(918) 459-2285
(918) 459-2350 FAX
__________________________________________________________________
This message may contain information that is privileged and confidential to
LaBarge, Inc.  It is for use only by the individual or entity named above.
If you are not the intended recipient, you may not copy, use or deliver this
message to anyone.  In such event, you should destroy the message and kindly
notify the sender by reply e-mail.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per
day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------




__________________________________________________________________
This message may contain information that is privileged and confidential to
LaBarge, Inc.  It is for use only by the individual or entity named above.
If you are not the intended recipient, you may not copy, use or deliver this
message to anyone.  In such event, you should destroy the message and kindly
notify the sender by reply e-mail.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet
NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send
e-mail to [log in to unmask]: SET Technet Digest Search the archives of
previous posts at: http://listserv.ipc.org/archives Please visit IPC web
site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2