I believe these are AVX's "flexible termination" chip caps and I believe
these are also base metal electrodes

Regards
Ian Fox
Goodrich ECS

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of James TerVeen
Sent: 11 April 2005 14:22
To: [log in to unmask]
Subject: Re: [TN] Hoy! John Maxwell, are you somewhere out there?


Ingemar it looks like you have been double plated.   Most terminations with
copper are for RF applications because they take the ferrous metal out of
the circuit.   I do not know why they would plate with copper and then
nickel over.  I would guess this may be the root of your problem.



                      "Ingemar Hernefjord
                      (KC/EMW)"                     To:
[log in to unmask]
                      <ingemar.hernefjord@ER        cc:
                      ICSSON.COM>                   Subject:  Re: [TN] Hoy!
John Maxwell, are you somewhere out there?
                      Sent by: TechNet
                      <[log in to unmask]>


                      04/11/05 03:06 AM
                      Please respond to
                      TechNet E-Mail Forum;
                      Please respond to
                      "Ingemar Hernefjord
                      (KC/EMW)"






adding cross section picture for Steve's gallery...
Ingemar

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]
Sent: den 11 april 2005 08:56
To: [log in to unmask]
Subject: [TN] Hoy! John Maxwell, are you somewhere out there?


John, need immediate advice from you, as you are being very familiar with
ceramic caps. Got problem with 0603 100nF/16VDC/X7R, Rins > 10-100 kOhms,
sometimes lower. Failure rate 1-2%.
Q: Terminals AgCuNiSnPb instead of usual AgNiSnPb. Never seen Cu before. Why
Cu? Thx in advance Ingemar Hernefjord Ericsson Microwave Systems

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------





STATEMENT OF CONFIDENTIALITY:

If you have received this e-mail in error, please immediately notify the
sender by e-mail at the address shown.  This e-mail and any attachments may
contain confidential information. This information is intended only for the
use of the individual(s) or entity to whom it is intended even if addressed
incorrectly.  Please delete it from your files if you are not the intended
recipient.  Thank you for your compliance.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To
unsubscribe, send a message to [log in to unmask] with following text in the
BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or
(re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet
NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send
e-mail to [log in to unmask]: SET Technet Digest Search the archives of
previous posts at: http://listserv.ipc.org/archives Please visit IPC web
site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2