Robert Coburn <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, [log in to unmask]
Date:
Wed, 16 Mar 2005 07:25:29 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (67 lines)
Rich;
I believe the sample size to volume limitation for the Omegameter 600 is 50
: 1.
As you probably know, controlling the rise of the test solution is
difficult to control at the very low end.
Trying to level off at 1000 ml's is tough when trying to test a 20 in2
sample.
Hope this helps.
Regards,
Rob



                      Rich Olsen
                      <rich@CIRCUITEXPR        To:       [log in to unmask]
                      ESS.COM>                 cc:
                      Sent by: TechNet         Subject:  [TN] Ionic Contamination Test
                      <[log in to unmask]>


                      03/15/2005 06:57
                      PM
                      Please respond to
                      TechNet E-Mail
                      Forum; Please
                      respond to Rich
                      Olsen






Hi All,

        What are the size limitations (on the small side) for testing ionic
contamination on an assembled board in an Omega Meter 600? What is an
acceptable ratio for Square Inches of total surface area versus solution
volume?

thanks,
Rich

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2