TECHNET Archives

March 2005

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Stephen Gregory <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, [log in to unmask]
Date:
Mon, 14 Mar 2005 20:52:12 -0600
Content-Type:
text/plain
Parts/Attachments:
text/plain (132 lines)
Les,

Send your images directly to me, and I will post them for everyone to
view...

Kind regards,

-Steve Gregory-
Senior Process Engineer
LaBarge Incorporated
Tulsa, Oklahoma
(918) 459-2285
(918) 459-2350 FAX



                      - Bogert
                      <[log in to unmask]>        To:       [log in to unmask]
                      Sent by: TechNet         cc:
                      <[log in to unmask]>        Subject:  [TN] Capacitor Terminal Silver Braze Problem


                      03/14/2005 06:12
                      PM
                      Please respond to
                      TechNet E-Mail
                      Forum; Please
                      respond to -
                      Bogert






March 14, 2005

Folks, the attached photographs show some type of problem with a silver to
ceramic braze joint.  The joint provides a seal around a capacitor
terminal.  The manufacturer rejected the terminal due to the noted
conditions.

In the photo titled top view, the white area on the outer diameter is a 90%
Alumina ceramic.

Next to the ceramic is the silver braze connection that connects the
ceramic to 304 stainless steel using Ag 2.5 silver solder (i.e.,
97.5PbAg2.5).

In the middle of the top view photo is a copper terminal.

The other three photos show the top view enlarged in the 8 o'clock, 4
o'clock and 10 o'clock positions.

As you can tell from the photographs, the silver braze joint appears
corroded.  Also, there appears to be poor or non-wetting to the 304 SST, or
otherwise a crack formed.

We used a knife in the area from the one o'clock position to about the 2
o'clock position and were able to easily scrape away the top surface of the
braze down to about a 1/64 inch or > depth till we got to solid braze area.

We had an analysis performed that did not show any chlorides, just silver
and lead.  It could be that the stuff we were able to scrape away is some
form of lead oxide, not sure.

I note that the historical QQ-S-571 specification in section 6 indicates
that Ag2.5 solder is subject to corrosion in a humid environment, as is
Ag5.5.  However, the QQ spec indicates that Ag1.5, which is used
interchangeably with Ag2.5, has better shelf life and will not develop a
black surface deposit.  I don't know if the corrosion for Ag2.5 means just
a black deposit, or if the solder joint will fail due to other type of
corrosion.  I note that J-STD-006 does not include the same information as
does section 6 of QQ-S-571.

During our qualification testing, we subjected a capacitor to high humidity
at high temp for an extended period of time with no evidence of corrosion.


Can you folks please answer the following questions?

1.  What caused the conditions shown in the photographs?  What are the
photographs showing?

2.  Would brazing (probably a furnace braze, not sure) at too high or too
low a temperature cause the condition?

3.  Will Ag2.5 corrode in a humid environment? If so, what type of
corrosion, and why can it occur?  Is it a black surface condition?, or can
the corrosion ultimately cause failure of the braze joint?  What is the
physical science basis for the corrosion?  Why does it only occur for
certain % of silver content, and not for all % of silver?

4.  Why doesn't J-STD-006 have the same info as QQ-S-571 regarding
corrosion of Ag2.5 and Ag5.5 solder?

5.  Will the corrosion continue?

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------




__________________________________________________________________
This message may contain information that is privileged and confidential to
LaBarge, Inc.  It is for use only by the individual or entity named above.
If you are not the intended recipient, you may not copy, use or deliver
this message to anyone.  In such event, you should destroy the message and
kindly notify the sender by reply e-mail.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2