TECHNET Archives

March 2005

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Bill Kasprzak <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, [log in to unmask]
Date:
Mon, 28 Mar 2005 08:33:49 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (76 lines)
Ramon,

Can  you indicate what the source of the tooling is? Is it exactly the
correct tooling for the terminal in question?

Another area I would look at is board thickness. Terminals have been
typically made for standard thickness of board materials such as .031,
.062, etc. I've had problems with boards coming in thinner than what the
terminal was made for. This makes the swage operation more difficult to do
without cracks and splits.

I've even used a small thin solderable washer on the turret side of a
terminal in order to have the proper thickness so the terminal will swage
properly.

Bill Kasprzak
Moog Inc
Process Engineer, Electronic Assembly



"Dehoyos, Ramon" <[log in to unmask]>
Sent by: TechNet <[log in to unmask]>
03/28/2005 08:16 AM
Please respond to
TechNet E-Mail Forum <[log in to unmask]>; Please respond to
"Dehoyos, Ramon" <[log in to unmask]>


To
[log in to unmask]
cc

Subject
[TN] Solder Terminals






        Hi Technetters:
      I would like to know if anybody has experienced difficulties in
flaring the flange of solder terminals. On J-std-001C 6.2.3 it states that
the angle of flare shall be between 35 and 120 deg. Some terminals crack
even if they are flared at 36 deg.  Other terminals can be flared at 120
deg and not crack. I suspect that the plating finish has a lot to do with
it.
        Regards,
        Ramon

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------