TECHNET Archives

March 2005

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Crepeau, Phil (Space Technology)" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Crepeau, Phil (Space Technology)
Date:
Mon, 21 Mar 2005 16:27:36 -0800
Content-Type:
text/plain
Parts/Attachments:
text/plain (41 lines)
sorry, but silicone would be the worst choice if condensible outgassing were a concern.  you should pass this one by a conformal coating vendor who could recommend an non-condensible outgassing conformal coating.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of DUTTON Phil
Sent: Monday, March 21, 2005 3:41 PM
To: [log in to unmask]
Subject: [TN] High V conformal coating


Hello,

I've been asked what to use as a conformal coating for a high voltage
circuit (<4kV).
Also we want low out gassing because of some sensitive optical
components.
I'm thinking a silicone would be ok. Any advice would be welcome.

thanks,

Phil Dutton C.I.D.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2