Hi folks!
I see what seems to be a contradiction in plating void criteria in the
IPC-6012 for Class 3. Table 3-3 (Plating and Coating Voids Visual
Examination) says "none" for copper voids allowed. Table 3-6 (Plated Hole
Integrity After Stress) says "one void allowed per specimen provided the
additional microsection criteria of 3.6.2.2 are met." Since voids are not
created by the stress, why would they be allowed after stress (in cross
section) but not before (seen visually)?
Thanks,
Debbie
Deborah S. Schepis
Quality Engineer
Endicott Interconnect Technologies
(607) 755-3152
email: [log in to unmask]
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------