I too have seen the gamut of "special rework" requests.  We will document the request, snap a few close-up digital pictures (if necessary), record any concerns that we may have and request that the customer sign off before the rework is implemented.

How's quadruple stacking of some 0805 components with a "teepee" of a diode and resistor combination over it?  That was just last week's "special rework" request.  

Rich

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Morse, Carrie
Sent: Friday, February 18, 2005 9:30 AM
To: [log in to unmask]
Subject: Re: [TN] Flipped transistor?

We see all sorts of "special rework" that our customers request.  Although the design of the rework may not be the most robust or the most "IPC Correct", the bottom line is that the Print takes Precedence.  Typically, when I see something like this, I blink my eyes a few times, shake my head, and document the info on a DFM report with my recommendations.  The only time something is really a "NO NO" is when the customer says "NO NO".

-Carrie 

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Bissonnette, Jean-Francois
Sent: Friday, February 18, 2005 10:25 AM
To: [log in to unmask]
Subject: [TN] Flipped transistor?

Here is a first for me!

Before I go ruffling some feathers I would like to have others opinion.  I've just been informed of a modification on a boards that requires to install a SOT23 NPN transistor to be fliped on its back in order to be soldered.  The poor leads are then bent backward to contact with the board's lands of some other component.

Engineering did not raise a flag on that yet... I'm worried to say the least because I'm convinced that this is a NO NO!  

Anyone has seen that in the past?

Thanks!

Jean-François

***** CONFIDENTIALITY NOTE *****
The content contained in this e-mail transmission is legally privileged and confidential information intended only for the use of the individual or entity named herein. If the reader of this transmission is not the intended recipient, you are hereby notified that any dissemination, distribution, or copying of this transmission is strictly prohibited.

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e To unsubscribe, send a message to [log in to unmask] with following text in the BODY (NOT the subject field): SIGNOFF Technet To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL) To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest Search the archives of previous posts at: http://listserv.ipc.org/archives Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2