Matthew: The immersion metals Au, Ag and Sn all have their pluses and
minuses, however I wouldn't be quite so quick to rule out OSP coatings.

In addition to having a lower cost Vs immersion metals, the newer generation
OSP's have the capability to stand up to the higher temperatures of lead
free reflow. Although a lot depends on your process i.e. type of oven,
atmosphere, solderpaste, number of passes, storage conditions, etc. We have
run considerable testing on OSP with lead free and not had issues.

Also if you require selective electroplated gold for such things as switches
and key pads. It will be much easier, cheaper and more available from a
fabrication standpoint than immersion metal processes.

I believe there may be a place for all four of these coatings depending on
board design and final requirements. Also don't forget about lead free HAL.


Regards

Michael Barmuta

Staff Engineer

Fluke Corp.

Everett WA

425-446-6076




-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Matthew Lamkin
Sent: Tuesday, February 15, 2005 6:57 AM
To: [log in to unmask]
Subject: Re: [TN] OSP process for PCB


Special applications such as?

I have the task of coming up with the lead free finishes that we are going
to use.
OSP will NOT be one of them (I have been told not to use it).

Changing to lead free has removed a few PCB suppliers from our lists.

Thank you,
Matthew Lamkin.



-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of George Milad
Sent: Tuesday, February 15, 2005 2:48 PM
To: [log in to unmask]
Subject: Re: [TN] OSP process for PCB


Immersion Tin is in use as a surface finish for specific applicatios, it is
not classified as an OSP (organic solderability preservative).
Some common OSPs are Benzotriazoles, Immidazoles and Benzimidazoles. they
are non metallic, organic compounds.
Hope this is helpful.

Best  regards

George Milad
[log in to unmask]
National Accounts Manager  for Technology
Uyemura International Corporation
Technical Center
240  Town LIne Rd
Southington CT 06489
(516) 901 3874 (mobile)
(860)  793-4011 (office)
(860) 793-4020  (fax)


---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2