For those of use still running through hole wave solder systems, what

would be the "recommended" RoHS compliant board that might use immersion

tin or ENIG and 2 oz. copper? 



-----Original Message-----

From: Leadfree [mailto:[log in to unmask]] On Behalf Of Whittaker, Dewey

(AZ75)

Sent: Thursday, February 17, 2005 9:48 AM

To: [log in to unmask]

Subject: Re: [LF] RoHS compliance PCB



Assuming you have met all the other requirements, a minimum Tg of 155 C

and

350 C decomposition temperature should give you a reasonable chance of

meeting your functional, as well as economical goals.

Dewey



-----Original Message-----

From: Leadfree [mailto:[log in to unmask]]On Behalf Of Smith, Rick

Sent: Thursday, February 17, 2005 7:38 AM

To: [log in to unmask]

Subject: Re: [LF] RoHS compliance PCB





Ken,



Check with your process guys. I have found increasing laminate

decomposition temperature to above 330 C is required, and moving to 170

Tg laminate is unnecessary and a cost adder with respect to 4/8 layer

computer boards.



Laminates with Tg 145, 150 survive LF BGA rework provided the

decomposition temperature is >330 C.



Anyone else working on laminates have input?? Please coment.



thanks







-----Original Message-----

From: Leadfree [mailto:[log in to unmask]] On Behalf Of Ken Patel

Sent: Wednesday, February 16, 2005 5:06 PM

To: [log in to unmask]

Subject: [LF] RoHS compliance PCB



All,



I have heard that Fab Houses are moving directly to Halogenfree process,

skipping middle step knowing that Halogenfree is next in line to be

implemented. As our current fabs are built using laminate made of Tg of

170

C or more with Nickel Gold surface finish, do you see any problem?







Do we have to worry besides updating the fab notes asking for RoHS

compliance? We expect fab house to build products based on impedance

requirement. Any comments, suggestion?







Re,



Ken Patel





------------------------------------------------------------------------

-------Leadfee Mail List provided as a service by IPC using LISTSERV

1.8d

To unsubscribe, send a message to [log in to unmask] with following text

in

the BODY (NOT the subject field): SIGNOFF Leadfree

To temporarily stop/(start) delivery of Leadree for vacation breaks

send: SET Leadfree NOMAIL/(MAIL)

Search previous postings at: http://listserv.ipc.org/archives

Please visit IPC web site

http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional

information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100

ext.2815

------------------------------------------------------------------------

-------



------------------------------------------------------------------------

----

---Leadfee Mail List provided as a service by IPC using LISTSERV 1.8d

To unsubscribe, send a message to [log in to unmask] with following text

in

the BODY (NOT the subject field): SIGNOFF Leadfree

To temporarily stop/(start) delivery of Leadree for vacation breaks

send:

SET Leadfree NOMAIL/(MAIL)

Search previous postings at: http://listserv.ipc.org/archives

Please visit IPC web site

http://www.ipc.org/contentpage.asp?Pageid=4.3.16

for additional information, or contact Keach Sasamori at [log in to unmask]

or

847-615-7100 ext.2815

------------------------------------------------------------------------

----

---



------------------------------------------------------------------------

-------Leadfee Mail List provided as a service by IPC using LISTSERV

1.8d

To unsubscribe, send a message to [log in to unmask] with following text

in

the BODY (NOT the subject field): SIGNOFF Leadfree

To temporarily stop/(start) delivery of Leadree for vacation breaks

send: SET Leadfree NOMAIL/(MAIL)

Search previous postings at: http://listserv.ipc.org/archives

Please visit IPC web site

http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional

information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100

ext.2815

------------------------------------------------------------------------

-------





-------------------------------------------------------------------------------Leadfee Mail List provided as a service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Leadfree
To temporarily stop/(start) delivery of Leadree for vacation breaks send: SET Leadfree NOMAIL/(MAIL)
Search previous postings at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-------------------------------------------------------------------------------

ATOM RSS1 RSS2