Hi Al! The short answer to your question is "yes" - if you are able to
completely reflow the Pbfree solderball on the BGA then the likelihood of
having solder joint integrity problems becomes low. There have been a
number of published papers on the topic and the majority show that allowing
the Pbfree solderball to completely reflow results in a uniform
microstructure. If you only achieve partial melting of the solderball or
just diffusion of the solderpaste into the solderball then you have a
nonuniform microstructure that doesn't play well with your use environment.
Some folks have suggested to just increase the Sn/Pb reflow temperatures if
there is a Pbfree BGA component present on an assembly but the temperature
increase impact on the other components can cause other problems! Rockwell
Collins is presenting a paper on a case study of Pbfree solderballs in a
Sn/Pb reflow process at the Toronto Pbfree conference in May 24-26. I
think Steve G. also has a picture of a Pbfree solderball microstructure
after going thru a Sn/Pb reflow process. Good Luck.
Dave Hillman
Rockwell Collins
[log in to unmask]
alan.kreplick@TER
ADYNE.COM
Sent by: TechNet To
<[log in to unmask]> [log in to unmask]
cc
01/25/2005 07:41 Subject
AM [TN] Lead-free BGA using Lead Paste
Please respond to
TechNet E-Mail
Forum
<[log in to unmask]>
; Please respond
to
alan.kreplick@TER
ADYNE.COM
Technetters:
What happens when using a lead-free BGA with SN63 paste profile (ie above
liquidus approx 60 seconds and peak temperature approx. 210)? I do not
know the alloy of the ball at this time.
Will the paste wet to the ball and form a reliable solder connection? Is
it similar to using non-eutectic balls or column-grid-arrays?
Do I need the ball to reflow?
Thanks in advance,
Al Kreplick
Sr. Mfg. Eng.
Teradyne, Inc.
500 Riverpark Drive
Mail Stop NR500 1-1
North Reading, MA 01864
Tel: 978-370-1726
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|