Is storing at 20-25deg.C in violation of the manufacturer's specification? What is the shelf life at 20-25deg.C?
Rob Carrillo
Quality Manager
North Atlantic Industries
Bohemia, Long Island, NY
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Leigh Jansen
Sent: Wednesday, January 19, 2005 11:58 AM
To: [log in to unmask]
Subject: Re: [TN] HumiSeal 1B73
Hello Rob,
I would recommend storing such a solvent based Acrylic conformal coating
between 20-25deg.C ideally, thereby having it ready to use in your
application. Any colder and you may have to wait a long time before it is at
operating/application temperature, particularly in 25litre drums. Any hotter
and you may suffer more rapid, undesirable evaporative losses of the
solvent, also causing higher odour levels.
Storing at this temperature means the viscosity is then controlled ready for
use straight out of the drum, as supplied. As you may know, a change of
5cps in viscosity can cause immense problems in selective coating
applications.
If odour and flammability limits are your reasons for cold storage, then
maybe you could address this by looking at a water based Acrylic ?
Hope this helps,
Leigh Jansen
Technical Support Manager
NEW - HumiSeal 1H2O BoV Aerosol - NEW
[log in to unmask]
Concoat Limited - Engineering Reliability in Electronics
www.concoat.co.uk
9-11 Fleet Road,Fleet, Hampshire GU51 3QF
Tel: +44 (0)1252 813706
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Dehoyos, Ramon
Sent: 19 January 2005 15:25
To: [log in to unmask]
Subject: Re: [TN] HumiSeal 1B73
Hi Rob:
There are plenty of inexpensive industrial refrigerators Hook up a
chart recorder to it and keep it at the temp you want. We use them for some
glues.
Regards,
Ramon
-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Rob Carrillo
Sent: Wednesday, January 19, 2005 9:25 AM
To: [log in to unmask]
Subject: [TN] HumiSeal 1B73
I am looking for some recommendations on how to store HumiSeal 1B73 under
the revised storage temp. of +10°C. We purchase the item in 5 gallon drums
and keep it at point of use. Refrigeration in the work cell may prove
difficult. Any suggestions would be appreciated unless we repackage into
smaller containers.
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|