Rick,

Can not definitively say what is best for you, but I have used the Dage 4000 for a great deal of microelectronics type of work.  It comes with interchangeable transducers - up to a 100 Kg shear transducer.

There are wire pull transducers for heavy aluminum wire that easily go up to the 1Kg range [I forget what their max is]

Here is a web site - http://www.dage-group.com/test_systems/view.cfm?content_id=924E045A-B049-4B84-9FD0017565F85542

If this link fails to take you into the Dage bond testers, just truncate it to dage-group.com and work you own way into bond testers.  Maybe they have something else that is better suited for you needs.

I am sure there is other equipment out there too.

Steve - Gentex Corp


-----Original Message-----
From: Rick Thompson [mailto:[log in to unmask]]
Sent: Tuesday, December 07, 2004 10:44 AM
To: [log in to unmask]
Subject: [TN] Pull or Shear Test Recommendations?


We're evaluating the purchase of equipment to do pull or shear testing of surface mounted components after assembly. Can anyone recommend reasonably priced benchtop units I should consider and the range of forces I should be looking at?  Component range would be passives up to larger array type packages (50mm).
 
Thanks in advance.
 
 
Rick Thompson
Sr. SMT Process Engineer
SMTEK International
 
+1 (805) 532-2800   x-193
[log in to unmask]
 
 

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2