No published references, just experience.  I have seen recent issues
associated with reworking a board where components were removed from a board
to correct a surface mount problem.  The board was not baked out adequately
to dry the component to be reworked.  In this particular case, it was an
expensive, functional, flip chip component that was being reworked.  The
component was a large BGA with a lot of Cu planes in the substrate,
including nearly solid P and G planes.  And the die was very large.
Moisture desorption from such a package demands water to diffuse a long
distance lateral to the die, or through the thick, multi-plane substrate.
The inadequate bakeout induced popcorn delamination of the underfill to die
interface, and destroyed the device.  I suspect this type of rework-induced
popcorn will occur with many types of components that are intended to be
reballed or reworked in some way and then re-placed back on the motherboard.
If the rework heat is not tightly localized, it may also be possible to
popcorn adjacent components that may also have saturated with water in a
high humidity environment.  If the popcorn does not cause component failure,
a partial delamination due to the popcorn effect could lead to subsequent
field failure if the area of delamination increases over time in the
application environment, causing wire or solder bump breaks, or leading to
device overheating.  So proper bake out of the entire board is important,
especially if the assembled board and components equilibrated with moisture
absorption in a high relative humidity environment prior to rework.


Best regards,
Leo

Director of Applications Engineering
ASAT, Inc.
3755 Capital of Texas Highway, Suite 100
Austin, Texas     78704

ph     512-383-4593
fx      512-383-1590
[log in to unmask]
www.asat.com


The information contained in this electronic message is CUSTOMER/SUPPLIER
PRIVILEGED AND CONFIDENTIAL INFORMATION intended only for the use of the
individual or entity named above. If the reader of this message is not the
intended recipient, you are hereby notified that any dissemination,
distribution and copying of this communication is strictly prohibited. If
you have received this communication in error, please immediately notify the
sender by electronic mail. Thank you.



-----Original Message-----
From: EMTC Ireland [mailto:[log in to unmask]]
Sent: Thursday, November 18, 2004 8:21 AM
To: [log in to unmask]
Subject: [TN] Field Failures and reworked PCAs?


Hi all,

I am working on a presentation to highlight the risks associated with
excessive rework cycles on a PCA for SnPb and ultimately Lead free
processes.

I was wondering if anyone from the Reliability world has any
pointers/references to show the actual rework process contribution as the
root cause of failure on field returns????  Just rough estimates/breakdowns
would be helpful (I wouldn't dream of asking you to stand over the data!!!)

All assitance appreciated
Rgds
Moss
Technical Chair

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
SMART Group Ireland

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2