Process Indicators, Oh yes what a dilemma. My suggestions are one, take a
stand, NO TOUCH UP OF PROCESS INDICATORS and
two take the soldering irons away from the people doing the touch up.

This has been a problem for over 40 years and we're still talking about it,
can you believe it?

Any additional heat applied to the board creates cumulative damage to the
laminate, we know that, we've experienced that, and we've trained to that.

What part of NO touchup don't they understand.

Hope this helps. I know it gets me hot under the collar when I hear things
like this and the inspectors are driving the quality, come on engineering do
your jobs.

Regards and thanks for allowing me to let off some steam.

Leo Lambert

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Charles Caswell
Sent: Tuesday, November 02, 2004 9:06 AM
To: [log in to unmask]
Subject: Re: [TN] Process Indicators...


Join the fight. I have been arguing this point for years. Just as bad are
rejections for class 3 defects on class 2 product. Better than 90% of our
class 2 will meet class 3

-----Original Message-----
From: Daan Terstegge [mailto:[log in to unmask]]
Sent: Tuesday, November 02, 2004 2:35 AM
To: [log in to unmask]
Subject: Re: [TN] Process Indicators...

Hi Steve,

I agree with you 100%
The description of process indicators, as written in the IPC-A610, says
it all. No discussion possible.

(hhmm, then why am I having so much discussion with our inspectors?
hhmm.,...??)




Best regards,

Daan Terstegge
PCB Assembly Department
Thales Land & Joint Systems

Tel        +31(0)35 524 8297
Fax       +31(0)35 524 8181
[log in to unmask]
Unclassified Email

>>> [log in to unmask] 11/02/04 02:01am >>>
Hi All!!

I've been getting into a number of debates about "Process Indicators"
as
described in the IPC-610...mostly with our inspectors. I know their
hearts are
in the right place, but it seems that many times they will reject the
assemblies with "Process Indicators" back to our operators to touch
them  up, so that
they look more like the "Target Condition", to be more cosmetically
pleasing.

I've tried to explain things as best I can, but find that sometimes
our
operators are touching up way more solder joints than they need
too...they're
being "trained", as it were, by our inspectors. The operators know that
if
something isn't "pretty" enough, it's going to come back to them...so
they're
putting more labor into product than they should.

I'm trying to find some way, any way, to be able to show our inspectors
 that
to touch-up something because it doesn't look like the target
condition,
doesn't mean one is making things any better...I understand that beauty
is in
the eye of beholder.

There was some talk in the past about the Intermetallic Layer being
thickened during subsequent reflow cycles, and causing fractures, but
Werner said
that he's never seen a failure because of a thick Intermetallic
layer.

Process Indicators may happen as spelled out in the -610, sometimes not
 only
because of the assembly process, but because of the design, or other
factors.

I look at Process Indicators as a "Flag" to investigate whether or not
the
issues can be addressed and resolved properly, if they can't be
resolved, then
it's not a defect. Am I wrong about this?

As always, TIA!

-Steve Gregory-



---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text
in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at:
http://listserv.ipc.org/archives
Please visit IPC web site
http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100
ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------

ATOM RSS1 RSS2