Kaye - if you check out the appendix of 4552 - ENIG spec you will see the
data for membrane switches - 1.5 million cycles before we stopped the test -
the board surface was perfect after the test. For the 4553 I Ag
specification we tested to 1 million cycles and are recommending its use for
non class 3 applications, concerns being the active and dynamic nature of
the surface.
Regards,
Gerard O'Brien
Photocircuits Corporation
Co-chair 4-14 plating committee.
-----Original Message-----
From: Kaye Clayo [mailto:[log in to unmask]]
Sent: Monday, November 01, 2004 4:10 PM
To: [log in to unmask]
Subject: [TN] Surface Finish for keypad membrane switches
Technet:
Is ENIG a good reliable surface finish for keypad membrane switches that
cannot be bussed to the edge of the board?
If not, what be a good surface finish for Lead-Free keypad switches.
Thank you in advance.
Kaye Clayo
CONFIDENTIALITY NOTE: This message is intended only for the use of the
individual or entity to which it is addressed and may contain information
that is privileged, confidential, and exempt from disclosure under
applicable law. If the reader of this notice is not the intended recipient,
you are hereby notified that any dissemination, distribution or copying of
this communication is strictly prohibited. If you have received this
communication in error, please notify the sender immediately.
____________________________________________________________________________
_
Scanned by IBM Email Security Management Services powered by MessageLabs.
For more information please visit http://www.ers.ibm.com
____________________________________________________________________________
_
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to
[log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16
for additional information, or contact Keach Sasamori at [log in to unmask] or
847-615-7100 ext.2815
-----------------------------------------------------
---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-615-7100 ext.2815
-----------------------------------------------------
|
|
|