TECHNET Archives

October 2004

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Thomas, Brian" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Thomas, Brian
Date:
Wed, 6 Oct 2004 10:32:06 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (80 lines)
Hi Victor,

I believe you applied the Referee Method incorrectly. I think you still
had
three corners against the granite block. (your R1-R2 of the Referee
Method
was close to your .042 measurement, and I would expect it to be half
that
measurement.)

Only 2 diagonal corners should be against the granite block (R2). The
other 2
diagonal corners should be raised to an equal height to each other (R1).
L in
your calculation should be the diagonal (14.75) not the length.

Hope this helps.

Brian

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Victor G. Hernandez
Sent: Wednesday, October 06, 2004 9:36 AM
To: [log in to unmask]
Subject: Re: [TN] Twist & Bow

I too placed an inquire to the TechNetters about this Task.   I did not
receive an adequate response.  Good luck

Victor,

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Karnwal, Pankaj
Sent: Wednesday, October 06, 2004 7:14 AM
To: [log in to unmask]
Subject: [TN] Twist & Bow

Dear Technetters hello,

Any body have the procedure for measuring the twist & bow as IPC 610 B
says the .75% allowed for SMD populated module.
how we measure this .75 % , in respect to what ?

BR
Pankaj Karnwal
Jr. Engineer QA

Barco Electronics System  (P) Ltd.
mailto:[log in to unmask]
www.barco.com



 ======================================================================
 This electronic message transmission and any attachments are
 confidential and may constitute legally privileged information of
 Bioveris Corporation. The information is intended for solely
 the use of recipient (recipient).  If you are not
 the intended recipient, you are hereby notified that any
 disclosure, copying, distribution or the taking of any action in
 reliance of this information is strictly prohibited. You are not
 authorized to retain it in any form nor to re-transmit it, and
 you should destroy this email immediately.

 If you have received this electronic transmission in error,
 please notify us by telephone (800-336-4436) or by electronic
 mail to the sender of this email, Thomas, Brian ([log in to unmask]),
 immediately.
 =====================================================================

---------------------------------------------------
Technet Mail List provided as a service by IPC using LISTSERV 1.8e
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt or (re-start) delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL or (MAIL)
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search the archives of previous posts at: http://listserv.ipc.org/archives
Please visit IPC web site http://www.ipc.org/contentpage.asp?Pageid=4.3.16 for additional information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
-----------------------------------------------------

ATOM RSS1 RSS2